a low-cost method for optical tomography

نویسندگان

mohsen erfanzadeh laser and plasma research institute, shahid beheshti university.g.c., tehran, iran.

saied alikhani laser and plasma research institute, shahid beheshti university.g.c., tehran, iran.

mohammad ali ansari laser and plasma research institute, shahid beheshti university.g.c., tehran, iran.

ezeddin mohajerani laser and plasma research institute, shahid beheshti university.g.c., tehran, iran.

چکیده

introduction: in this study, arrangement of a low-cost optical tomography device compared to other methods such as frequency domain diffuse tomography or time domain diffuse tomography is reported. this low-cost diffuse optical imaging technique is based on the detection of light after propagation in tissue. these detected signals are applied to predict the location of in-homogeneities inside phantoms. the device is assessed for phantoms representing homogenous healthy breast tissues as well as those representing healthy breast tissues with a lesion inside. methods: a diode laser at 780nm and 50 mw is used as the light source. the scattered light is then collected from the outer surface of the phantom by a detector. both laser and detector are fiber coupled. the detector fiber may turn around the phantom to collect light scattered at different angles. phantoms made of intralipid as the scattering medium and ink as the absorbing medium are used as samples. light is collected after propagation in the phantoms and the capability of the device in collecting data and detecting lesions inside the phantoms is assessed. the fact that the detection fiber orbits around the sample and detects light from various angles has eliminated the need to use several detectors and optical fibers. the results obtained from experiments are compared with the results obtained from a finite element method (fem) solution of diffusion equation in cylindrical geometry written in fortran. results: the graphs obtained experimentally and numerically are in good accordance with each other. the device has been able to detect lesions up to 13 mm inside the biological phantom. conclusion: the data achieved by the optical tomography device is compared with the data achieved via a fem code written in fortran. the results indicate that the presented device is capable of providing the correct pattern of diffusely backscattered and transmitted light. the data achieved from the device is in excellent correlation with the numerical solution of the diffusion equation. therefore, results indicate the applicability of the reported device. this device may be used as a base for an optical imaging. it is also capable of detecting lesions inside the phantoms

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficient Method for Model Reduction in Diffuse Optical Tomography

We present an efficient method for the reduction of model equations in the linearized diffuse optical tomography (DOT) problem. We first implement the maximum a posteriori (MAP) estimator and Tikhonov regularization, which are based on applying preconditioners to linear perturbation equations. For model reduction, the precondition is split into two parts: the principal components are consid...

متن کامل

Domain decomposition method for diffuse optical tomography

Diffuse optical tomography is modelled as an optimization problem to find the absorption and scattering coefficients that minimize the error between the measured photon density function and the approximated one computed using the coefficients. The problem is composed of two steps: the forward solver to compute the photon density function and its Jacobian (with respect to the coefficients), and ...

متن کامل

Computational calibration method for optical tomography.

We propose a computational calibration method for optical tomography. The model of the calibration scheme is based on the rotation symmetry of source and detector positions in the measurement setup. The relative amplitude losses and phase shifts at the optic fibers are modeled by complex-valued coupling coefficients. The coupling coefficients can be estimated when optical tomography data from a...

متن کامل

Iterative boundary method for diffuse optical tomography.

The recent application of tomographic methods to three-dimensional imaging through tissue by use of light often requires modeling of geometrically complex diffuse-nondiffuse boundaries at the tissue-air interface. We have recently investigated analytical methods to model complex boundaries by means of the Kirchhoff approximation. We generalize this approach using an analytical approximation, th...

متن کامل

Direct Sampling Method for Diffusive Optical Tomography

In this work, we are concerned with the di↵usive optical tomography (DOT) problem in the case when only one or two pairs of Cauchy data is available. We propose a simple and e cient direct sampling method (DSM) to locate inhomogeneities inside a homogeneous background and solve the DOT problem in both full and limited aperture cases. This new method is easy to implement and less expensive compu...

متن کامل

A Low-Cost Fiducial Reference Phantom for Computed Tomography

To detect the growth in lesions, it is necessary to ensure that the apparent changes in size are above the noise floor of the system. By introducing a fiducial reference, it may be possible to detect smaller changes in lesion size more reliably. We suspend three precision spheres with a precision structure built from pieces from a popular children's building toy. We measure the distances betwee...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of lasers in medical sciences

جلد ۳، شماره ۳، صفحات ۱۰۲-۱۰۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023