the effect of carbon dioxide (co2) laser irradiation on sandblasting with large grit and acid etching (sla) surface

نویسندگان

tahereh foroutan department of biology, faculty of biological science, kharazmi university, tehran, iran

nader ayoubian department of periodontology, faculty of dentistry, azad university, branch of tehran, tehran, iran

چکیده

introduction: the purpose of this study was to investigate the effect of 6w power carbon dioxide laser (co2) on the biologic compatibility of the sandblasting with large grit and acid etching (sla) titanium discs through studying of the sarcoma osteogenic (saos-2) human osteoblast-like cells viability. methods: sterilized titanium discs were used together with saos-2 human osteoblast-like cells. 6 sterilized sla titanium discs of the experimental group were exposed to irradiation by co2 laser with a power of 6w and 10.600nm wavelength, at fixed frequency of 80hz during 45 seconds in both pulse and non-contact settings. saos-2 human osteoblast-like cells were incubated under 37° c in humid atmosphere (95% weather, 5% co2) for 72 hours. mtt test was performed to measure the ratio level of cellular proliferation. results: the results indicated that at 570nm wavelength, the 6w co2 laser power have not affected the cellular viability. conclusion: co2 laser in 6w power has had no effect on the biologic compatibility of the sla titanium surface

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Carbon Dioxide (CO2) Laser on Sandblasting with Large Grit and Acid Etching (SLA) Surface.

INTRODUCTION The purpose of this study was to investigate the effect of 6W power Carbon Dioxide Laser (CO2) on the biologic compatibility of the Sandblasting with large grit and acid etching (SLA) titanium discs through studying of the Sarcoma Osteogenic (SaOS-2) human osteoblast-like cells viability. METHODS Sterilized titanium discs were used together with SaOS-2 human osteoblast-like cells...

متن کامل

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

OBJECTIVES The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. MATERIALS AND METHODS The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements...

متن کامل

effect of surface treatment with carbon dioxide (co2) laser on bond strength between cement resin and zirconia

introduction: since it is not possible to form an adequate micromechanical bond between resin cement and zirconia ceramics using common surface treatment techniques, laser pretreatment has been suggested for zirconia ceramic surfaces. the aim of this study was to evaluate the effect of carbon dioxide (co 2 ) laser treatment on shear bond strength (sbs) of resin cement to zirconia ceramic. metho...

متن کامل

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

PURPOSE This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. METHODS This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to...

متن کامل

Effect of CO2 laser irradiation on the surface of the polycrystalline ceramic bracket and the rate of canine movement with sliding mechanic

Introduction: Metal brackets are the most commonly used brackets in clinical orthodontics, but the sight of color of the metal bracket can be unpleasant for some patients. Ceramic brackets offer the desired beauty but they have higher frictional resistance.  Considering that in vitro studies suggest that CO2 laser reduces the friction between the wire and slot of the bracket in the sliding mech...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of lasers in medical sciences

جلد ۴، شماره ۲، صفحات ۸۶-۹۱

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023