diffuse optical tomography: image reconstruction and verification

نویسندگان

mohammad ali ansari laser and plasma research institute, shahid beheshti university. g.c.,tehran, iran

mohsen erfanzadeh laser and plasma research institute, shahid beheshti university. g.c.,tehran, iran

zeinab hosseini laser and plasma research institute, shahid beheshti university. g.c.,tehran, iran

ezzedin mohajerani laser and plasma research institute, shahid beheshti university. g.c.,tehran, iran

چکیده

introduction: in this study, we intend to use diffuse optical tomography (dot) as a noninvasive, safe and low cost technique that can be considered as a functional imaging method and mention the importance of image reconstruction in accuracy and procession of image. one of the most important and fastest methods in image reconstruction is the boundary element method (bem). this method is introduced and employed in our works. method: generally, to image a biological tissue we must obtain its optical properties. in order to reach this goal we benefit from diffusion equation because tissue is highly scattering medium. diffusion equation is solved by boundary element equation (bem) in our research. first, we assume a double layer phantom with different scattering and absorption coefficients to simulate and verify precession and accuracy of image reconstruction by bem. light absorption can be affected by volume fraction of blood in skin. for a specific skin species the volume fraction is calculated and then the results are compared with the reconstructed values obtained by bem. since the depth of tissue is important in light absorption a two layer phantom with known values is made and the depths of layers are reconstructed by bem then they are compared with the expected values. a homogenous phantom with known scattering and absorption coefficients was made and then these coefficients were reconstructed by bem. finally, an inhomogeneous phantom (phantom with defect) whose defect was in a known position was made and the absorption and scattering coefficients were reconstructed and compared with real values. results: comparison between real or simulated values and reconstructed values of scattering and absorption coefficients, volume fraction of blood and thickness of phantom layers by bem shows maximum errors of 24%, 7% and 35%, respectively. conclusion: comparison between bem data and real or simulated values shows an acceptable agreement. consequently, we can rely on bem as a beneficial method in diffuse optical tomography image reconstruction .

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffuse optical tomography: image reconstruction and verification.

INTRODUCTION In this study, we intend to use diffuse optical Tomography (DOT) as a noninvasive, safe and low cost technique that can be considered as a functional imaging method and mention the importance of image reconstruction in accuracy and procession of image. One of the most important and fastest methods in image reconstruction is the boundary element method (BEM). This method is introduc...

متن کامل

Hyperspectral image reconstruction for diffuse optical tomography

We explore the development and performance of algorithms for hyperspectral diffuse optical tomography (DOT) for which data from hundreds of wavelengths are collected and used to determine the concentration distribution of chromophores in the medium under investigation. An efficient method is detailed for forming the images using iterative algorithms applied to a linearized Born approximation mo...

متن کامل

Numerical modelling and image reconstruction in diffuse optical tomography.

The development of diffuse optical tomography as a functional imaging modality has relied largely on the use of model-based image reconstruction. The recovery of optical parameters from boundary measurements of light propagation within tissue is inherently a difficult one, because the problem is nonlinear, ill-posed and ill-conditioned. Additionally, although the measured near-infrared signals ...

متن کامل

Contrast-detail analysis characterizing diffuse optical fluorescence tomography image reconstruction.

Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to...

متن کامل

Gauss-Newton method for image reconstruction in diffuse optical tomography.

We present a regularized Gauss-Newton method for solving the inverse problem of parameter reconstruction from boundary data in frequency-domain diffuse optical tomography. To avoid the explicit formation and inversion of the Hessian which is often prohibitively expensive in terms of memory resources and runtime for large-scale problems, we propose to solve the normal equation at each Newton ste...

متن کامل

Constrained Reconstruction Techniques for Diffuse Optical Tomography

Three-dimensional diffuse optical tomography (DOT) attempts to map in vivo tissue blood oxygenation and blood volume levels by reconstructing the spatial distribution of the optical absorption coefficient from intensity measurements on the surface of the body. This problem is typically ill-posed due to the large attenuation and scattering of the diffuse wave. In addition, certain applications, ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of lasers in medical sciences

جلد ۵، شماره ۱، صفحات ۱۳-۱۸