transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

نویسندگان

behnaz sedighi

hossein ali ebrahimi

shirin jabbarpour

kaveh shafiee

چکیده

background: an imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. the purpose of this study was to determine the transcranial doppler sonography (tds) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. methods: this study was carried out on 46 patients (23 cases and 23 controls). we used doppler instrument via trans-temporal window and detected middle cerebral artery, anterior cerebral artery and posterior cerebral artery by 2 mhz probe. the flow velocity in the posterior cerebral artery before, during and immediately after stimulation was recorded. stimulation was done using a flickering light in 100 seconds. results: at the baseline, the middle cerebral artery had more peak systolic velocity in migraineurs than the control group. although peak systolic velocity changes in the mid-photic period is not statistically significant. on the other hand, post-photic peak systolic velocity increased significantly. the diagnostic accuracy of the peak systolic volume (psv) changes in the posterior cerebral artery (pca) for the migraine was 72.3%. conclusion: this stimulation we found altered cerebral vasomotor reactivity in the interictal phase in migraineurs with visual aura. this seemed to be an unavoidable hindrance for the wider implementation of functional tcd in diagnostic work up of migraine patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...

متن کامل

Interhemispheric comparisons of cerebral blood flow velocity changes during mental tasks with transcranial Doppler sonography.

OBJECTIVE The purpose of this study was to evaluate hemispheric asymmetry of cerebral blood flow changes during various mental tests by applying transcranial Doppler sonography (TCD) to simultaneously monitor bilateral cerebral blood flow velocity changes. METHODS Twenty-one participants without cerebrovascular disease performed 3 left hemispheric tasks (reading, calculation, and color scalin...

متن کامل

Cerebral arteriovenous malformations: diagnostic value of echo-enhanced transcranial Doppler sonography compared with angiography.

BACKGROUND AND PURPOSE The purpose of our study was to examine the clinical value of echo-enhanced transcranial power Doppler sonography (EE-TCD), including it ability to assess hemodynamic parameters of the intracranial vasculature, in patients with suspected cerebral arteriovenous malformations (AVMs) and to compare this method with angiography. METHODS Sixteen patients with suspected cereb...

متن کامل

Transcranial Doppler assessment of cerebral flow velocity during cognitive tasks.

BACKGROUND AND PURPOSE The purpose of this study was to assess the ability of transcranial Doppler ultrasonography to detect selective circulatory changes during cognitive activity. METHODS We measured cerebral artery flow velocity in 21 normal volunteers by transcranial Doppler ultrasonography during rest followed by cerebral activation. Mean and peak systolic flow velocities of the anterior...

متن کامل

Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography.

BACKGROUND AND PURPOSE The angle of insonation cannot be assessed with conventional transcranial Doppler sonography. Findings in healthy control subjects suggest that the angle is relatively small in routine clinical practice. Data regarding the angle in middle cerebral artery (MCA) stenosis are scarce. In this study, the angle and its effect on flow velocity measurements were assessed with tra...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
caspian journal of internal medicine

جلد ۲، شماره ۱، صفحات ۱۷۸-۱۸۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023