detection of staphylococcus enterotoxin b (seb) using an immunochromatographic test strip
نویسندگان
چکیده
results in total, 80 food samples suspected of seb contamination were assessed using the two methods. fifty-four samples were contaminated based on the pcr technique and twenty-six of those were confirmed using the strip assay. conclusions the sensitivity of the sandwich method was approximately 10 ng/ml and that of the competitive method was approximately 250 ng/ml. in the lfd, a highly specific monoclonal antibody used for both the sandwich and competitive methods resulted in an increased sensitivity and accuracy for the detection of a minimal seb concentration. materials and methods the strip assays were compared with pcr, a valid method for detection. for pcr, a specific sequence for seb production was detected using primers designed according to genbank sequences. objectives in our laboratory, the production of an immunochromatographic test strip, for the detection of seb using a sandwich assay and a competitive method, was described; the test can detect seb with high sensitivity. background staphylococcus aureus is one of the most important microorganisms that causes various human diseases by secreting virulence factors known as staphylococcal super antigens (sags). staphylococcal enterotoxin b (seb) is a bacterial antigen that is responsible for food poisoning in humans. among seb detection methods, a lateral flow device (lfd) is ideal for rapid immunochromatographic tests because it is easy to use, requires minimal time to produce results, and does not require personnel training.
منابع مشابه
Detection of Staphylococcus Enterotoxin B (SEB) Using an Immunochromatographic Test Strip
BACKGROUND Staphylococcus aureus is one of the most important microorganisms that causes various human diseases by secreting virulence factors known as staphylococcal super antigens (SAgs). Staphylococcal Enterotoxin B (SEB) is a bacterial antigen that is responsible for food poisoning in humans. Among SEB detection methods, a lateral flow device (LFD) is ideal for rapid immunochromatographic t...
متن کاملDevelopment of an Immunochromatographic Test Strip for Detection of Cholera Toxin
Because cholera toxin (CT) is responsible for most of the symptoms induced by Vibrio cholerae infection, detection of CT is critical for diagnosis of the disease. In this study, we constructed an immunochromatographic test strip for detection of CT (CT-IC) with polyclonal antibodies developed against purified recombinant whole CT protein. The detection limit of the CT-IC was 10 ng/mL of purifie...
متن کاملDevelopment of an Immunochromatographic Strip Test for Rapid Detection of Ciprofloxacin in Milk Samples
A rapid, simple, and sensitive immunochromatographic test strip has been developed for testing residues of ciprofloxacin (CIP). A specific and sensitive monoclonal antibody (mAb) for CIP was generated by immunizing BALB/c mice with well-characterized CIP-Keyhole limpet haemocyanin. Under the optimized conditions, the cut-off limits of test strips for CIP were found to be 5 ng/mL in phosphate-bu...
متن کاملDevelopment of an Immunochromatographic Strip Test for the Rapid Detection of Alternariol Monomethyl Ether in Fruit
A rapid, portable, and semi-quantitative immunochromatographic strip was developed for rapid and visual detection of alternariol monomethyl ether (AME). For this purpose, the anti-AME monoclonal antibody (mAb) was prepared and identified. AME coupled to bovine serum albumin (BSA) via methyl 4-bromobutanoate was prepared as immunogen. The recoveries of AME in spiked cherry and orange fruits dete...
متن کاملAn immunochromatographic test strip for rapid detection of fish pathogen Edwardsiella tarda
Background: Edwardsiella tarda, the etiologic agent of edwardsiellosis, is a devastating fish pathogen prevailing in worldwide aquaculture industries and accounting for severe economic losses. There is a raising concern about E. tarda being a significant zoonotic pathogen, and it is urgent to develop a rapid detection of this pathogen. This is the first study to develop a test strip for rapid d...
متن کاملA fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.
A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
jundishapur journal of microbiologyجلد ۸، شماره ۹، صفحات ۰-۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023