beam hardening artifacts by dental implants: comparison of cone‑beam and 64‑slice computed tomography scanners
نویسندگان
چکیده
background: cone beam computed tomography (cbct) is an alternative to a computed tomography (ct) scan, which is appropriate for a wide range of craniomaxillofacial indications. the long‑term use of metallic materials in dentistry means that artifacts caused by metallic restorations in the oral cavity should be taken into account when utilizing cbct and ct scanners. the aim of this study was to quantitatively compare the beam hardening artifacts produced by dental implants between cbct and a 64‑slice ct scanner. materials and methods: in this descriptive study , an implant drilling model similar to the human mandible was used in the present study. the implants (dentis) were placed in the canine, premolar and molar areas. three series of scans were provided from the implant areas using somatom sensation 64‑slice and newtom vgi (cbct) ct scanners. identical images were evaluated by three radiologists. the artifacts in each image were determined based on pre‑determined criteria. kruskal‑wallis test was used to compare mean values; mann‑whitney u test was used for two‑by‑two comparisons when there was a statistical significance ( p < 0.05). results: the images of the two scanners had similar resolutions in axial sections ( p = 0.299). in coronal sections, there were significant differences in the resolutions of the images produced by the two scanners ( p < 0.001), with a higher resolution in the images produced by newtom vgi scanner. on the whole, there were significant differences between the resolutions of the images produced by the two ct scanners ( p < 0.001), with higher resolution in the images produced by newtom vgi scanner in comparison to those of somatom sensation. conclusion: given the high quality of the images produced by newtom vgi and the lower costs in comparison to ct, the use of the images of this scanner in dental procedures is recommended, especially in patients with extensive restorations, multiple prostheses and previous implants. key words: beam hardening artifacts, cone beam computed tomography, dental implants
منابع مشابه
Beam Hardening Artifacts: Comparison between Two Cone Beam Computed Tomography Scanners
BACKGROUND AND AIMS At present, cone beam computed tomography (CBCT) has become a substitute for computed tomography (CT) in dental procedures. The metallic materials used in dentistry can produce artifacts due to the beam hard-ening phenomenon. These artifacts decrease the quality of images. In the present study, the number of artifacts as a result of beam hardening in the images of dental imp...
متن کاملbeam hardening artifacts: comparison between two cone beam computed tomography scanners
background and aims. at present, cone beam computed tomography (cbct) has become a substitute for computed tomography (ct) in dental procedures. the metallic materials used in dentistry can produce artifacts due to the beam hardening phenomenon. these artifacts decrease the quality of images. in the present study, the number of artifacts as a result of beam hardening in the images of dental imp...
متن کاملEffective dose range for dental cone beam computed tomography scanners.
OBJECTIVE To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. MATERIALS AND METHODS Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100 H) which were evenly distributed throughout the head and neck, covering all radiosensitiv...
متن کامل[Comparison of absorbed and effective dose from two dental cone beam computed tomography scanners].
OBJECTIVE This research compared the field of view with the tissue absorbed dose and effective doses using the two dental cone beam computed tomography (CBCT) scanners. MATERIALS AND METHODS Two CBCT devices, an Alphard VEGA and 3DX multi-image micro CT MCT-1, were used. Measurements were made using an Alderson RANDO phantom and thermoluminescence dosimeters (TLDs). The calculation of the eff...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملAssessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography
OBJECTIVE The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). METHODS Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalga...