the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants
نویسندگان
چکیده
background: mechanical torque limiting devices (mtlds) are necessary tools to control a peak torque and achieving target values of screw component of dental implants. due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices (f-s mtlds) in achieving their target torque values. materials and methods: peak torque measurements of 15 new f-s mtlds from three different manufacturers (astra tech, biohorizons, dr. idhe) were measured ten times before and after 100 steam sterilization using a digital torque gauge. to simulate the clinical situation of aging (number of use) target torque application process was repeated 10 times after each sterilization cycle and the peak torque values were registered. comparison of the mean differences with target torque in each cycle was performed using one sample t test. considering the type of mtlds as inter subject comparison, one-way repeated measure anova was used to evaluate the absolute values of differences between devices of each manufacturer in each group (α = 0.05). results: the results of this study in dr. idhe group showed that, mean of difference values signifi cantly differed from the target torque ( p = 0.002) until 75 cycles. in astra tech group, also mean of difference values with under estimation trend, showed a signifi cant difference with the target torque ( p < 0.001). mean of difference values signifi cantly differed from the target torque with under estimation trend during all the 100 cycles in biohorizons group ( p < 0.05). conclusion: the torque output of each individual device stayed in 10% difference from target torque values before 100 sterilization cycles, but more than 10% difference from the target torque was seen in varying degrees during these consequent cycles. key words: calibration, dental implants, equipment failure, torque
منابع مشابه
the effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.
high variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (f-s mtlds). the effect of aging (number of use) on the accuracy of these devices is not clear. the purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of f-s mtlds.fifteen new f-s mtlds and their appropriate drivers from three differ...
متن کاملThe effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants
BACKGROUND Mechanical torque limiting devices (MTLDs) are necessary tools to control a peak torque and achieving target values of screw component of dental implants. Due to probable effect of autoclaving and number of use on the accuracy of these devices, this study aimed to evaluate the effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devic...
متن کاملthe effect of aging on the accuracy of spring-style mechanical torque limiting devices for dental implants
objective: recently, a wide variation has been reported in delivery of the target torque by spring-style mechanical torque limiting devices (mtlds) but the effect of aging on their accuracy has not been independently evaluated. the purpose of this study was to determine the effect of aging on the accuracy of spring-style mtlds. methods: in this in-vitro experimental study, 15 new spring-style m...
متن کاملThe Effect of Aging on the Accuracy of New Friction-Style Mechanical Torque Limiting Devices for Dental Implants
OBJECTIVE High variability in delivering the target torque is reported for friction-style mechanical torque limiting devices (F-S MTLDs). The effect of aging (number of use) on the accuracy of these devices is not clear. The purpose of this study was to assess the effect of aging on the accuracy (±10% of the target torque) of F-S MTLDs. MATERIALS AND METHODS Fifteen new F-S MTLDs and their ap...
متن کاملthe effect of task complexity on lexical complexity and grammatical accuracy of efl learners’ argumentative writing
بر اساس فرضیه شناخت رابینسون (2001 و 2003 و 2005) و مدل ظرفیت توجه محدود اسکهان (1998)، این تحقیق تاثیر پیچیدگی تکلیف را بر پیچیدگی واژگان و صحت گرامری نوشتار مباحثه ای 60 نفر از دانشجویان زبان انگلیسی بررسی کرد. میزان پیچیدگی تکلیف از طریق فاکتورهای پراکندگی-منابع تعیین شد. همه ی شرکت کنندگان به صورت نیمه تصادفی به یکی از سه گروه: (1) گروه موضوع، (2) گروه موضوع + اندیشه و (3) گروه موضوع + اندی...
15 صفحه اولThe effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants
BACKGROUND Mechanical torque devices (MTDs) are one of the most commonly recommended devices used to deliver optimal torque to the screw of dental implants. Recently, high variability has been reported about the accuracy of spring-style mechanical torque devices (S-S MTDs). Joint stability and survival rate of fixed implant supported prosthesis depends on the accuracy of these devices. Currentl...