a comparative evaluation of working length with digital radiography and third generation apex locator (propex) in the presence of various intracanal irrigants: an in vivo/ex vivo study

نویسندگان

irfana khursheed

ruchika bansal

tajinder bansal

harkanwal preet singh

چکیده

background: accurate working length determination is a pre-requisite for a successful endodontic treatment. even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. the purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using direct digital radiographic method (radiovisiography or rvg) and propex electronic apex locator in the presence of three different irrigating solutions: 0.9% normal saline, 2% chlorhexidine, 3% naocl solutions. materials and methods: forty single-rooted human teeth scheduled for extraction with mature apices were selected for this study. measurements were performed by using rvg and propex in the presence of irrigating solutions. after extraction of the teeth, light microscope was used to confi rm visually the relationship of the tip of the endodontic fi le to the apical foramen, and actual lengths were determined by reducing 0.5 mm from this length. the statistical analysis was performed by one-way anova test and tukey-hsd post hoc procedure. p < 0.05 was considered as signifi cant. results: no signifi cant difference was found between overall mean electronic working length and digital radiographic length; however, prediction error ( p < 0.05) was signifi cant with respect to different irrigants. among the irrigating solutions, chlorhexidine gluconate had the smallest distance to the actual lengths, whereas naocl had the greatest. conclusion: electronic apex locator propex yielded best result in the presence of chlorhexidine, whereas the largest error was demonstrated with naocl indicating that higher electroconductive irrigating solutions affect the precision of multi-frequency apex locators. key words: apex locators, digital radiography, irrigation solutions, working length

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study

BACKGROUND Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using Direct Digita...

متن کامل

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

a comparative study of the relationship between self-, peer-, and teacher-assessments in productive skills

تمایل به ارزیابی جایگزین و تعویض آن با آزمون سنتی مداد و کاغذ در سالهای اخیر افزایش یافته است. اکثر زبان آموزان در کلاس های زبان از نمره نهایی که استاد تعیین میکند ناراضی اند. این تحقیق جهت بررسی ارزیابی در کلاس های زبان انگلیسی به هدف رضایتمندی زبان آموزان از نمره هایشان انجام گرفته است که در آن نمرات ارائه شده توسط سه گروه ارزیاب (ارزیابی خود دانشجو، همسالان واستاد) در مهارت های تولید (تکل...

15 صفحه اول

A Comparative Evaluation of Accuracy of New-generation Electronic Apex Locator with Conventional Radiography to determine Working Length in Primary Teeth: An in vivo Study

AIMS The purpose of this study was to evaluate the accuracy of a new-generation electronic apex locator (iPex) to determine working length in primary teeth with or without root resorption as compared with the conventional radiographic method. MATERIALS AND METHODS A sample of 30 primary posterior teeth which are indicated for pulpectomy were selected for the study. After obtaining the informe...

متن کامل

a comparative study of the theme of "marriage" in three victorian novelists: charles dickens, george eliot and thomas hardy

این تحقیق کوشیده است با انتخاب پنج رمان از میان آثار برگزیده، «چارلز دیکنز»، «جورج الیوت» و «توماس هاردی » و با رویکردی تطبیقی به بررسی درونمایه ی «ازدواج» در آثار این سه رمان نویس بزرگ دوره ی ویکتوریا بپردازد. فرضیه ی اولیه ی تحقیق این بوده است که چارلز دیکنز (1870- 1812) با زبانی شوخ و گزنده، جورج الیوت(1880- 1819) با نگاهی آموزشی–اندرزگونه و توماس هاردی(1928- 1840) با رویکردی تلخ وانتقادی به...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
dental research journal

جلد ۱۱، شماره ۱، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023