accuracy and reliability of linear measurements using tangential projection and cone beam computed tomography

نویسندگان

mahnaz sheikhi

mansour dakhil-alian

zahra bahreinian

چکیده

background: providing a cross-sectional image is essential for preimplant assessments. computed tomography (ct) and cone beam ct (cbct) images are very expensive and provide high radiation dose. tangential projection is a very simple, available, and low-dose technique that can be used in the anterior portion of mandible. the purpose of this study was to evaluate the accuracy of tangential projection in preimplant measurements in comparison to cbct. materials and methods: three dry edentulous human mandibles were examined in five points at intercanine region using tangential projection and cbct. the height and width of the ridge were measured twice by two observers. the mandibles were then cut, and real measurements were obtained. the agreement between real measures and measurements obtained by either technique, and inter- and intra-observer reliability were tested. results: the measurement error was less than 0.12 for tangential technique and 0.06 for cbct. the agreement between the real measures and measurements from radiographs were higher than 0.87. tangential projection slightly overestimated the distances, while there was a slight underestimation in cbct results. conclusion: considering the low cost, low radiation dose, simplicity and availability, tangential projection would be proper for preimplant assessment in edentulous patients when limited numbers of implants are required in the anterior mandible, and there is no need for more complicated image modalities.  key words: cone beam computed tomography, dental implant, radiograph

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

accuracy of linear measurements using cone beam computed tomography in comparison with clinical measurements

objectives: this study sought to evaluate the accuracy and errors of linear measurements of mesiodistal dimensions of kennedy class iii edentulous space using cone beam computed tomography (cbct) in comparison with clinical measurements. materials and methods: nineteen kennedy class iii dental arches were evaluated. an impression was made of each dental arch and poured with dental stone. the di...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Accuracy and reliability of stitched cone-beam computed tomography images

PURPOSE This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. MATERIALS AND METHODS Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gu...

متن کامل

Accuracy of Linear Measurements Using Cone Beam Computed Tomography in Comparison with Clinical Measurements

OBJECTIVES This study sought to evaluate the accuracy and errors of linear measurements of mesiodistal dimensions of Kennedy Class III edentulous space using cone beam computed tomography (CBCT) in comparison with clinical measurements. MATERIALS AND METHODS Nineteen Kennedy Class III dental arches were evaluated. An impression was made of each dental arch and poured with dental stone. The di...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

Accuracy of Linear Measurements of Galileos Cone Beam Computed Tomography in Normal and Different Head Positions

Introduction. The aim of this study was to determine the accuracy of linear measurements in dry human skulls in ideal position and different deviated positions of the skull. Methods. 6 dry human skulls were included in the study. Opaque markers were attached to alveolar bone. Buccolingual and mesiodistal distances and heights were measured in 5 different regions of either jaws using a digital c...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
dental research journal

جلد ۱۲، شماره ۳، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023