accuracy of different impression materials in parallel and nonparallel implants
نویسندگان
چکیده
background: a precise impression is mandatory to obtain passive fi t in implant-supported prostheses. the aim of this study was to compare the accuracy of three impression materials in both parallel and nonparallel implant positions. materials and methods: in this experimental study, two partial dentate maxillary acrylic models with four implant analogues in canines and lateral incisors areas were used. one model was simulating the parallel condition and the other nonparallel one, in which implants were tilted 30° bucally and 20° in either mesial or distal directions. thirty stone casts were made from each model using polyether (impregum), additional silicone (monopren) and vinyl siloxanether (identium), with open tray technique. the distortion values in three-dimensions (x, y and z-axis) were measured by coordinate measuring machine. two-way analysis of variance (anova), one-way anova and tukey tests were used for data analysis (α = 0.05). results: under parallel condition, all the materials showed comparable, accurate casts ( p = 0.74). in the presence of angulated implants, while monopren showed more accurate results compared to impregum ( p = 0.01), identium yielded almost similar results to those produced by impregum ( p = 0.27) and monopren ( p = 0.26). conclusion: within the limitations of this study, in parallel conditions, the type of impression material cannot affect the accuracy of the implant impressions; however, in nonparallel conditions, polyvinyl siloxane is shown to be a better choice, followed by vinyl siloxanether and polyether respectively. key words: dental implants, dental impression materials, dental impression techniques,polyvinyls
منابع مشابه
Accuracy of impressions with different impression materials in angulated implants.
PURPOSE To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. MATERIALS AND METHODS Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were ...
متن کاملan investigation of accuracy and complexity across different proficiency levels in written narrative task
abstract this quasi-experimental study was aimed at examining the impact of storyline complexity on the grammatical accuracy and complexity of advanced and intermediate efl learners. a total of 65 advanced and intermediate efl learners were selected from iran language institute (ili). an intact group including 35 intermediate participants and another intact group with 30 advanced participants ...
Three-dimensional accuracy of different impression techniques for dental implants
BACKGROUND Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. MATERIALS AND METHODS Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BI...
متن کاملAccuracy of stone casts obtained by different impression materials.
Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full cro...
متن کاملthree-dimensional accuracy of different impression techniques for dental implants
background: accurate impression making is an essential prerequisite for achieving a passive fi t between the implant and the superstructure. the aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. materials and methods: three acrylic resin mandibular master models with four parallel implants were used: biohorizons (b...
متن کاملAccuracy of the implant impression obtained from different impression materials and techniques: review
With the predictable integration of implants, the emphasis is shifted towards precise prosthesis. Reproducing the intraoral relationship of implants through impression procedures is the first step in achieving an accurate, passively fitting prosthesis. The critical aspect is to record the three dimensional orientation of the implant as it is present intraorally, other than reproducing fine surf...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
dental research journalجلد ۱۲، شماره ۴، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023