volume fraction and location of voids and gaps in ultraconservative restorations by x-ray computed micro-tomography
نویسندگان
چکیده
background: volume fraction (vf) and location of internal voids and gaps in relation to material type and cavity dimensions in ultraconservative restorations were investigated in this study. materials and methods: forty-eight round cavities of 1.3 mm mean diameter and 2.6 mm mean depth were made on buccal and lingual surfaces of recently extracted human teeth. these were fi lled and thermocycled with two low viscosity composites (aeliteflo lv [af], permaflo [pf]), one high viscosity composite (aelite aesthetic enamel [aa]) and one glass-ionomer (gcfuji ix gp). x-ray microtomography, following a specifi c procedure, was applied to all cavities before and after their restoration, using skyscan-1072 microtomographer. vf percent (vf%) and location of voids and gaps were recorded and analysed statistically at a = 0.05. kruskal-wallis nonparametric analysis of variance, post-hoc analysis, mann-whitney test, spearman’s correlation analysis were used to analyze data. results: cavities fi lled with af and pf showed signifi cantly lower vf% of voids and gaps than all other restorations ( p < 0.05). only for the cavities fi lled with aa, cavity width and depth was signifi cantly correlated with vf% ( p < 0.05). 50-75% of the fi lled cavities contained internal voids regardless of the restorative material ( p > 0.05). the proportion of cavities with gaps at the bottom and side walls was lower in those fi lled with af and pf ( p < 0.05). conclusion: cavities fi lled with low viscosity composites presented the lowest amount of internal voids and gaps. glass-ionomer and high viscosity composite restorative materials showed the highest amount of interfacial gaps. only in the high viscosity composite restorations the amount of voids and gaps correlated with the cavity depth, width and volume. key words: cavity preparations, composite resin, dental, dental marginal adaptations, microcomputed tomography, x-ray
منابع مشابه
X-ray micro-computed tomography
Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitablecontrast agent, blood vessels have beenimaged and analysed quantitatively such asblood volume and vessel sizes on embryosof ages 14.5 to 16.5 days old. The advantageof using this imaging modality is that it hasprovide...
متن کاملFast volume scanning approaches by X-ray-computed tomography
X-ray-computed tomography (CT) successfully underwent a transition from slice-by-slice imaging to volume imaging in the decade after 1990 due to the introduction of spiral scan modes. Later, the transition from single-slice to multislice scanning followed. With the advent of new detector technologies we are now looking forward to circular and spiral scanning using area detectors and the respect...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملQuantification of eggshell microstructure using X-ray micro computed tomography
1. X-ray microcomputed tomography can be used to produce rapid, fully analysable, three-dimensional images of biological and other materials without the need for complex or tedious sample preparation and sectioning. We describe the use of this technique to visualise and analyse the microstructure of fragments of shell taken from three regions of chicken eggs (sharp pole, blunt pole and equatori...
متن کاملIn-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation
The complex mechanical behaviour of composite materials, due to internal heterogeneity and multi-layered composition impose deeper studies. This paper presents an experimental investigation technique to perform volume kinematic measurements in composite materials. The association of X-ray micro-computed tomography acquisitions and Digital Volume Correlation (DVC) technique allows the measuremen...
متن کاملX-ray computed tomography.
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictio...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
dental research journalجلد ۱۲، شماره ۶، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023