evaluation of threshold response and appropriate electrode placement site for electric pulp testing in fluorosed anterior teeth: an in vivo study
نویسندگان
چکیده
background: accurate diagnosis is key to success. diagnosing the pulpal status in varied clinical situations poses a challenge to the clinician. electric pulp test (ept) is one of the valuable attempts in evaluating the sensibility of pulp tissue. the aim of this study was to find out and compare the threshold levels and optimal electrode placement site for ept in fluorosed and nonfluorosed anterior teeth. materials and methodology: eighty volunteers recruited for this study were divided into two groups based on the incidence of dental fluorosis. electric pulp testing was done on either of the central incisors in fluorosed and nonfluorosed group. four sites on each crown were tested 4 times with digitest electric pulp tester, and the mean of the threshold responses was recorded. the data were analyzed with spss, version 11. means of variables from each location were compared using one-way anova and tukey’s post-hoc test while the critical level of significance was set at p < 0.05. results: the mean and standard deviation of threshold levels in fluorosed teeth were greater when compared to that of nonfluorosed teeth at all sites with incisal edge showing the least mean threshold levels for both the groups (p > 0.05). conclusion: it was concluded that fluorosed teeth responded to high threshold levels, and incisal edge was the optimal electrode placement site. key words: dental fluorosis, diagnosis, electric pulp test, electrode placement site, threshold response
منابع مشابه
Appropriate electrode placement site for electric pulp testing of anterior teeth in Nigerian adults: a clinical study.
Electric pulp testing is one of the pulp vitality tests which aid dentists in diagnosis of the pulp status. This test is technique sensitive and hence may elicit false responses. There are some concerns regarding the optimal placement of the probe tip. The threshold value (the lowest electric current at which sensation is perceived) is reached when an adequate number of nerve fibers are stimula...
متن کاملdevelopment and implementation of an optimized control strategy for induction machine in an electric vehicle
in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...
15 صفحه اولan investigation into iranian teachers consistency and bias in evaluation of students writings
while performance-based language assessment has led to an increased authenticity and content validity in the practice of writing assessment, the reliability of ratings has become a major issue. research findings have shown different reactions by native english speaker (nes) and non-native english speaker (nns) teachers to students’ writings. the focus of this study is on investigating whether i...
an appropriate model for exchange rate predictability in iran: comparing potential forecastability
nowadays in trade and economic issues, prediction is proposed as the most important branch of science. existence of effective variables, caused various sectors of the economic and business executives to prefer having mechanisms which can be used in their decisions. in recent years, several advances have led to various challenges in the science of forecasting. economical managers in various fi...
بررسی اثر محل قرارگیری الکترود پالپ تستر در پاسخ دندانهای قدامی فک بالا
Background and Aims: Electric pulp testing is used for diagnosis of the pulp status. This test is technique sensitive and hence may elicit positive or negative false response in case of inaccurate use. The optimal site for placement of the probe tip has not been determined. The aim of this study was to evaluate the effect of pulp tester probe placement site on the response of maxillary teeth.Ma...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
dental research journalجلد ۱۳، شماره ۳، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023