comparison of permeability of an iranian latex glove with two types of imported gloves after one time usage

نویسندگان

بهجت الملوک بهجت الملوک عجمی

behjatalmolook ajami دانشیار دندانپزشکی کودکان، مرکز تحقیقات دندانپزشکی، دانشگاه علوم پزشکی مشهد علیرضا علیرضا صراف شیرازی

alireza sarrafshirazi associate professor of pediatric dentistry, dental research center, mashhad university of medical sciences, mashhad, iranدانشیار دندانپزشکی کودکان، مرکز تحقیقات دندانپزشکی، دانشگاه علوم پزشکی مشهدسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) ترانه ترانه موحد

taraneh movahhed assistant professor, dept of pediatric dentistry, dental school, mashhad university of medical sciences, mashhad, iranاستادیار گروه دندانپزشکی کودکان، دانشکده دندانپزشکی، دانشگاه علوم پزشکی مشهدسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) فرناز فرناز چهرازی

farnaz chehrazi dentistدندانپزشکسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

چکیده

introduction: gloves protect the dental healthcare worker from direct contact with microorganisms in the patient's mouth and on dental setting surfaces; they also protect the patient from potential pathogens on the hands of the clinicians. this study was performed to evaluate the permeability of three types of examination latex gloves after treatment of patients in pediatric department of mashhad school of dentistry. materials & methods: a total of 60 pairs of three types of gloves (supa, medic-dent and super max) and five gloves of each type as control were randomly selected. the effective barrier properties were investigated following one hour treatment including fluoride therapy, amalgam and tooth colored restoration and pulp therapy. the effect of sex and the difference between working and non working hands were assigned too. the permeability of the case and control groups was determined by an electrical test. the voltage of each glove was registered at a current of 0.6 ma, using salt electrolyte solution. the data were analyzed using spss statistical software (t-test and anova). results: comparison of mean voltage of used glove with control in each type showed no significant difference except in super max (p=0). unlike supa and medic-dent gloves, greater permeability was detected in super max glove after treatment. the mean voltage of working and non working hand between gloves was not significant (p=0.19). conclusion: according to this study there was not any difference in permeability of iranian glove (supa) before and after use.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a comparison of linguistic and pragmatic knowledge: a case of iranian learners of english

در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...

15 صفحه اول

Glove over glove technique for manipulation of vinyl polysiloxane impression material with latex gloves

Despite prior recommendations for removal, latex gloves remain prevalent in dental clinical practice because of puncture resistance, durability, and user satisfaction.[1] However, latex gloves can impair polymerization of vinyl polysiloxane impression material (VPS) thus, resulting in inaccurate and distorted impressions, which may require the clinician to repeat the impression procedure leadin...

متن کامل

the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine

abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...

15 صفحه اول

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله دانشکده دندانپزشکی مشهد

جلد ۳۴، شماره ۲، صفحات ۱۴۳-۱۵۲

کلمات کلیدی
introduction gloves protect the dental healthcare worker from direct contact with microorganisms in the patient's mouth and on dental setting surfaces they also protect the patient from potential pathogens on the hands of the clinicians. this study was performed to evaluate the permeability of three types of examination latex gloves after treatment of patients in pediatric department of mashhad school of dentistry. materials & methods a total of 60 pairs of three types of gloves (supa medic dent and super max) and five gloves of each type as control were randomly selected. the effective barrier properties were investigated following one hour treatment including fluoride therapy amalgam and tooth colored restoration and pulp therapy. the effect of sex and the difference between working and non working hands were assigned too. the permeability of the case and control groups was determined by an electrical test. the voltage of each glove was registered at a current of 0.6 ma using salt electrolyte solution. the data were analyzed using spss statistical software (t test and anova). results comparison of mean voltage of used glove with control in each type showed no significant difference except in super max (p=0). unlike supa and medic dent gloves greater permeability was detected in super max glove after treatment. the mean voltage of working and non working hand between gloves was not significant (p=0.19). conclusion according to this study there was not any difference in permeability of iranian glove (supa) before and after use.