evaluation of accuracy, precision and agreement of five hba1c measurement methods with hplc reference method

نویسندگان

mohammad taha jalali department of clinical biochemistry

hajie bibi shahbazian department of endocrinology

mohammad reza afsharmanesh department of clinical biochemistry

rohollah mousavi dehmordi department of clinical biochemistry

چکیده

abstract         background and objective: the current challenge of diabetes mellitus is to prevent its complications. these complications are directly associated with hyperglycemia in diabetics. the hba1c measurement is essential for long-term glycemic control. synchronization of hba1c measurement is important in order to avoid discrepancies between results reported by laboratories. this study aimed to evaluate the accuracy, precision and agreement of five hba1c measurement methods with hplc reference method.        methods: hba1c levels of 55 samples were measured using six methods of microcapillary electrophoresis (sepia), enzymatic method (pishtaz teb), immunoturbidometry (pars azmoon), boronate affinity (nycocard), immunofluorescence (ichroma) and tosoh g8 hplc.        results: the five tested methods showed a good agreement with the hplc method with correlation coefficient of less than 95%. regression testing of hplc method and other methods showed slope of 0.99 (p<0.05) for sebia, 1.02 (p<0.05) for pishtaz teb, 0.79 (p<0.05) for pars azmoon, 0.82 (p<0.05) for nycocard and 0.89 (p<0.05) for ichroma. average inaccuracy for the sebia, pishtaz teb, pars azmoon, nycocard and ichroma in comparison with the hplc reference method were -0.09, -0.004, -0.75, -0.79 and -0.78, respectively.          conclusion: the sebia microcapillary method and pishtaz teb enzymatic method have appropriate accuracy and precision. therefore, these methods can be used as alternatives to the hplc method for hba1c measurement. other methods such as pars azmoon, nycocard and ichroma have significant shortcomings in terms of accuracy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Accuracy, Precision and Agreement of Five Hba1c Measurement Methods with HPLC Reference Method

ABSTRACT &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objective: The current challenge of diabetes mellitus is to prevent its complications. These complications are directly associated with hyperglycemia in diabetics. The HbA1c measurement is essential for long-term glycemic control. Synchronization of HbA1c measurement is important in order to avoid discrepancies between resu...

متن کامل

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Abstract &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...

متن کامل

the effects of error correction methods on pronunciation accuracy

هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...

15 صفحه اول

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

Modified HPLC-electrospray ionization/mass spectrometry method for HbA1c based on IFCC reference measurement procedure.

BACKGROUND Monitoring of hemoglobin A(1c) (HbA(1c)) is important in the management of diabetes. The IFCC reference measurement procedure for HbA(1c) is based on the ratio of glycated to nonglycated N-terminal hexapeptides of the beta-chains of hemoglobin after digestion with Glu-C endoproteinase. We developed a modification of the original reference measurement procedure with HPLC-electrospray ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
medical laboratory journal

جلد ۱۰، شماره ۲، صفحات ۵۸-۶۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023