intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients

نویسندگان

حیدر امینی

heidar amini علیرضا خدابنده

alireza khodabande ساسان مقیمی

sasan moghimi یداله اسلامی

yadollah eslami رضا زارعی

چکیده

purpose: to quantify the intraobserver reproducibility of retinal nerve fiber layer (rnfl) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. methods: twenty-six eyes of 26 glaucoma suspect patients were included. complete ophthalmologic examination and standard automated perimetry were performed for all of them. rnfl measurements were done using gdx-vcc (laser diagnostic technologies, san diego , ca ) by an experienced operator. the test repeated immediately by the same operator. results: patients were 24 to 70 years old (55.9±11.5 years). twenty patients were female and 6 patients were male. eighteen patients were ocular hypertensive and 8 patients had large cup to disk ratios. none of them had glaucomatous field defect in standard perimetry. the mean coefficient of variation for measurements of tsnit average (avg), superior avg, inferior avg, tsnit-sd and nerve fiber indicator (nfi) were 0.77, 0.95, 0.91, 0.81, and 0.98 respectively. the mean coefficient of variation of gdx-vcc was 88.4 for the 5 main parameters (tsnit avg, superior avg, inferior avg, tsnit-sd, and nfi). conclusion: gdx-vcc showed a good test-retest correlation and acceptable intraobserver reproducibility. nfi may be the most reproducible major gdx-vcc parameter in glaucoma suspect patients.   iranian journal of ophthalmology 200719(4):21-27

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients

Purpose: To quantify the intraobserver reproducibility of retinal nerve fiber layer (RNFL) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. Methods: Twenty-six eyes of 26 glaucoma suspect patients were included. Complete ophthalmologic examination and standard automated perimetry were performed for all of them. RNFL measurements were...

متن کامل

Detection of progressive retinal nerve fiber layer loss in glaucoma using scanning laser polarimetry with variable corneal compensation.

PURPOSE To evaluate the ability of scanning laser polarimetry with variable corneal compensation to detect progressive retinal nerve fiber layer (RNFL) loss in glaucoma patients and patients suspected of having the disease. METHODS This was an observational cohort study that included 335 eyes of 195 patients. Images were obtained annually with the GDx VCC scanning laser polarimeter, along wit...

متن کامل

Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation.

OBJECTIVE To investigate the longitudinal corneal birefringence (corneal polarization axis [CPA] and corneal polarization magnitude [CPM]) variability in scanning laser polarimetry with variable corneal compensation and its effect on retinal nerve fiber layer measurements. Method We analyzed scanning laser polarimetry images obtained every 6 months for 3.2 years in 16 healthy eyes, 38 eyes with...

متن کامل

Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients

PURPOSE To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). MATERIALS AND METHODOLOGY 114 eyes of patients with moderate open angle glaucoma underwent spectral dom...

متن کامل

Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.

PURPOSE To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurement...

متن کامل

Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects.

PURPOSE To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. METHODS Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and ach...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۱۹، شماره ۴، صفحات ۲۱-۲۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023