axial length measurement in asteroid hyalosis: comparing laser interferometry and ultrasound a-scan
نویسندگان
چکیده
purpose : to compare laser interferometry (li) and ultrasound a-scan in measurement of axial length ( al ) in eyes with asteroid hyalosis methods : twenty three patients with unilateral moderate to severe asteroid hyalosis determined by b-scan ultrasonography images participated in the study. the al measurements were obtained by li and ultrasound a-scan in both asteroid hyalosis and noninvolved eyes. the measurements were performed by the two methods as well as for affected and contralateral normal eyes and were statistically compared using the paired t-test. a p-value less than 0.05 was considered significant. results : the ultrasound al measurements were taken in every case but measurement with the li method was not possible in 4 eyes with asteroid hyalosis (17.3%). there was a high correlation between li and ultrasound a-scan measurements in both asteroid hyalosis and noninvolved eyes (r2=0.97, p<0.001 and r2=0.95, p<0.001 respectively). there was no significant difference between al taken by either method in asteroid hyalosis and noninvolved eyes. conclusion : the failure rate of al measurement using li was relatively high in eyes with asteroid hyalosis. there was a high correlation between al measured by ultrasound a-scan and li method in both asteroid hyalosis and noninvolved eyes. iranian journal of ophthalmology 200921(1):29-34 © 2009 by the iranian society of ophthalmology
منابع مشابه
Axial Length Measurement in Asteroid Hyalosis: Comparing Laser Interferometry and Ultrasound A-scan
© 2009 by the Iranian Society of Ophthalmology Published by Otagh-e-Chap Inc. 29 Purpose: To compare laser interferometry (LI) and ultrasound A-scan in measurement of axial length (AL) in eyes with asteroid hyalosis Methods: Twenty three patients with unilateral moderate to severe asteroid hyalosis determined by B-scan ultrasonography images participated in the study. The AL measurements were o...
متن کاملBilateral asteroid hyalosis revealing a blood imbalance
Asteroid hyalosis is an age related vitreous degeneration of unknown etiology, usually described to be unilateral. It's characterized by aggregation of calcium soaps in vitreous body. This benign condition has been reported to be frequently associated to many systemic disorders including diabetes mellitus, systemic arterial hypertension, atherosclerotic vascular disease, hypercholesterolemia an...
متن کاملMeasurement of the axial length of cataract eyes by laser Doppler interferometry.
PURPOSE To examine the applicability of the recently developed laser Doppler interferometry technique for measuring the axial length of cataract eyes in a realistic clinical situation. To determine the performance of the instrument as a function of cataract grade. To compare the results to those of ultrasound methods. METHODS A total of 196 cataract eyes of 100 patients were examined. The axi...
متن کاملLow visual acuity and asteroid hyalosis
A 56 years old man was admitted to the ophthalmology department for low visual acuity since his 45 years old with no amelioration after optic correction. The physical exam found visual acuity at 1/10 on the right eye and 9/10 on the left one, clear cornea, intraocular pressure at 14 mmhg on both eyes, the fundus of the right eye showed multiple yellow mobile vitreous particles that are absent o...
متن کاملMeasurement of changes in optical path length and reflectivity with phase-shifting laser feedback interferometry.
The operating characteristics of a novel phase-shifting interferometer are presented. Interference arises by reflecting the light from a sample back into the cavity of a cw He-Ne laser. Changes in phase and fringe visibility are calculated from an overdetermined set of phase-shifted intensity measurements with the phase shifts being introduced with an electro-optic modulator. The interferometer...
متن کاملMeasurement of Bunch Length Using Intensity Interferometry
Abstract Intensity interferometry is one of the most conventional methods for measuring the length of a short light pulse (from ps to sub-ps). We attempted to apply this method to the measurement of bunch length at the Photon Factory. We tested both the second-harmonic autocorrelation method and the two-photon interference method. With both methods, we observed the autocorrelation signal of the...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of current ophthalmologyجلد ۲۱، شماره ۱، صفحات ۲۹-۳۴
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023