comparison of central corneal thickness measurements with pentacam, orbscan ii, and ultrasound pachymeter

نویسندگان

عباسعلی یکتا

abbas-ali yekta حسن هاشمی

hassan hashemi مهدی خبازخوب

mehdi khabazkhoob اصغر دوستدار

asghar dostdar شیوا مهرآوران

چکیده

purpose: to compare thickness of central cornea measured using pentacam, orbscan ii, and ultrasound pachymeter methods: patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. central corneal thickness (cct) was measured by three methods using pentacam, orbscan ii, and ultrasound pachymeter. results: comparison of ultrasound and orbscan cct measurements showed a relatively high correlation between these two devices (p<0.001 r=0.891). the 95% limits of agreement (loa) between these two devices were -42.44 to 20.18 µm. there was also a high correlation between the results obtained through ultrasound and pentacam (p<0.001 r=0.932). the 95% loa of cct with ultrasound and pentacam were -13.35 to 24.16 µm. there was also a high correlation between cct measurements carried out by orbscan and pentacam (p<0.001) and the 95% loa were -12.14 to 45.19 µm. conclusion: the findings of the present study demonstrated high agreements between the cct readings measured with orbscan, pentacam, and ultrasound. the agreement between the pentacam and ultrasound measurements was higher than that of between orbscan and ultrasound, making pentacam a better substitute for ultrasound.   iranian journal of ophthalmology 200921(2):51-57 © 2009 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

Purpose: To compare thickness of central cornea measured using Pentacam, Orbscan II, and ultrasound pachymeter Methods: Patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. Central corneal thickness (CCT) was measured by three metho...

متن کامل

Comparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals

Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...

متن کامل

[Reliability of corneal thickness measurements by Orbscan II and ultrasound pachymeter].

PURPOSE To access the reliability of corneal thickness measurements by Orbscan II and ultrasound pachymeter. METHODS A retrospective study of 134 eyes from 67 normal subjects between January and June 2001 was obtained. Sex, age, visual acuity, refractive error and corneal thickness measurements by Orbscan II and ultrasound pachymetry were evaluated. All results were analyzed by the paired t t...

متن کامل

Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.

PURPOSE To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR. METHODS Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb...

متن کامل

Central Corneal Thickness Measurement by Ultrasound versus Orbscan II

PURPOSE To compare Orbscan II and ultrasonic pachymetry for measurement of central corneal thickness (CCT) in eyes scheduled for keratorefractive surgery. METHODS CCT was measured using Orbscan II (Bausch & Lomb, USA) and then by ultrasonic pachymetry (Tomey SP-3000, Tomey Ltd, Japan) in 100 eyes of 100 patients with no history of ocular surgery scheduled for excimer laser refractive surgery....

متن کامل

Central corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam.

PURPOSE To evaluate the agreement among three different optical methods in measuring anterior chamber depth (ACD), central corneal thickness (CCT), and pupil diameter. METHODS One hundred eyes of 50 healthy patients (25 men, 25 women) were enrolled in the study. Mean patient age was 25 years (range: 21 to 32 years). Exclusion criteria were history of any intraocular or corneal surgery, contac...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۱، شماره ۲، صفحات ۵۱-۵۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023