relationship between the gdx vcc and stratus oct in primary open angle glaucoma

نویسندگان

علی عبداللهی

ali abdollahi محمدرضا پنجتن پناه

mohammad reza panjtan panah حیدر امینی

heydar amini قاسم فخرایی

ghasem fakhraei رضا زارعی

چکیده

purpose : to compare the ability of scanning laser polarimetry (gdx vcc), and optical coherence tomography (oct) to discriminate eyes with primary open angle glaucoma (poag) from normal eyes and to assess the relationship between their parameters methods : eighty-seven glaucomatous eyes of 87 patients and 25 normal eyes were enrolled. the mean age of patients and normal group were 54.96±18.34 and 50.02±20.15, respectively. all subjects underwent a full ophthalmic examination, automated perimetry, gdx vcc and oct. correlation coefficients between the parameters of oct and gdx vcc were calculated. we calculated area under the receiver operating characteristic curve (aroc) for gdx vcc and oct main parameters. results : statistically significant correlations were observed between gdx vcc and oct parameters. pearson coefficients ranged from 0.731 for inferior average to -0.858 for nerve fiber indicator (nfi)/average thickness of oct. the greatest area under aroc parameter in oct (inferior average 0.97) had a lower area than that in gdx vcc (nfi 0.99). there was a significant statistical correlation in all visual field (vf), gdx vcc, and oct variables between two groups. conclusion : many parameters of gdx vcc were significantly correlated with those of the oct. inferior average and nfi had the greatest area under aroc parameter in oct and gdx vcc, respectively. nfi had high sensitivity and specificity for the diagnosis of poag.   iranian journal of ophthalmology 200921(4):55-62 © 2009 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between the Retinal Thickness Analyzer and the GDx VCC Scanning Laser Polarimeter, Stratus OCT Optical Coherence Tomograph, and Heidelberg Retina Tomograph II Confocal Scanning Laser Ophthalmoscopy

PURPOSE To assess the relationship between the retinal thickness analyzer (RTA) parameters, and those of the GDx VCC scanning laser polarimeter (GDx VCC), Stratus OCT optical coherence tomography (Stratus OCT), and Heidelberg retinal tomograph II confocal scanning laser ophthalmoscopy (HRT II). METHODS Twenty-nine primary open-angle glaucoma patients were retrospectively included in this stud...

متن کامل

The relationship between standard automated perimetry and GDx VCC measurements.

PURPOSE To investigate the relationship between retinal light sensitivity measured with standard automated perimetry (SAP) and retardation of the peripapillary retinal nerve fiber layer (RNFL) measured with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA). METHODS Forty-seven healthy subjects and 101 patients with glaucoma were examined with SAP and with the commercially avail...

متن کامل

Association between p53 Codon 72 (Arg72Pro) Polymorphism and Primary Open-Angle Glaucoma in Iranian Patients

Background: Glaucomatous neuropathy is a type of cell death due to apoptosis. The p53 gene is one of the regulatory genes of apoptosis. Recently, the association between the p53 gene encoding for proline at codon 72 and primary open-angle glaucoma (POAG) has been studied in some ethnic groups. This study is the first association analysis of POAG and p53 codon 72 polymorphism in Iranian patients...

متن کامل

Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma

BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...

متن کامل

Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma.

OBJECTIVE To compare the abilities of current commercially available versions of 3 optical imaging techniques: scanning laser polarimetry with variable corneal compensation (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]), and optical coherence tomography (Stratus OCT) to discriminate between healthy eyes and eyes with glaucomatous visual field loss. ME...

متن کامل

Primary open-angle glaucoma

 Primary open-angle glaucoma (POAG) is an idiopathic disorder in which the resistance to outflow through the trabecular meshwork gradually increases and the intraocular pressure (IOP) rises, causing irreversible damage to the optic nerve  POAG is the second most common cause of vision loss in the U.S.  Usually asymptomatic until advanced visual field loss has occurred; less than 50% of those...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۱، شماره ۴، صفحات ۵۵-۶۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023