laser in situ keratomileusis for the treatment of refractive errors in patients with multiple sclerosis
نویسندگان
چکیده
purpose : to assess the outcomes of laser in situ keratomileusis (lasik) in patients with multiple sclerosis (ms) methods : 15 eyes of 8 patients with ms (2 men and 6 women) who referred for myopia treatment (with or without astigmatism) were undergone lasik. after refractive and visual acuity examinations, topographic and pachymetry screening, intraocular pressure (iop) measurement, biomicroscopy and retinal examination, those eligible for the lasik surgery were included in the study. patients with any signs and symptoms of optic neuritis in at least 6 months prior to the surgery were excluded. the patients were followed-up between 6 months (one patient) to 5 years after surgery. mean spherical equivalent (se), uncorrected visual acuity (ucva) and best corrected visual acuity (bcva) of the patients were recorded at 6 month after surgery. follow-ups were done at the same day of the surgery and a week, 1, 6 months, and on annual basis after surgery. results : mean age of the patients was 28.88±6.38 years and the ms diagnosis in patients dated back to 5.31±3.83 years before the study. the first episode of attacks happened 1.04±0.59 years after surgery. mean se of patients was -4.10±1.67 d before surgery that improved to -0.27±0.29 d after it. mean ucva of the patients was 0.11±0.07 before surgery and improved to 0.86±0.18 after surgery. mean bcva of the patients was 0.89±0.18 before and after surgery. paired sample t-test showed significant differences between mean se and mean ucva differences both before and after surgery. conclusion : in our study, lasik seems to be a safe surgery in ms patients. iranian journal of ophthalmology 201022(3):9-12 © 2010 by the iranian society of ophthalmology
منابع مشابه
results of photorefractive keratectomy plus mitomycin-c in the treatment of regressed refractive errors after laser in situ keratomileusis
purpose : to investigate the application of mitomycin-c 0.02% (mmc) in the photorefractive keratectomy (prk) procedure in correcting regressed myopia methods : eighteen eyes of 11 patients with a spherical equivalent (se) of less than -5 diopters (d) who had undergone laser in situ keratomileusis (lasik) more than 2 years before were operated on. at the end of the prk procedure, mmc was applied...
متن کاملmodern surgical techniques in treatment of patients with cleft lip & cleft palate
چکیده ندارد.
15 صفحه اولResults of topography-guided laser in situ keratomileusis custom ablation treatment with a refractive excimer laser.
PURPOSE To evaluate the safety and effectiveness of topography-guided custom ablation treatment (T-CAT) to correct myopia and myopic astigmatism with laser in situ keratomileusis (LASIK). SETTING Nine clinical sites in the USA. DESIGN Prospective observational nonrandomized unmasked study. METHODS The study comprised patients aged 18 to 65 years old with myopia or myopic astigmatism with ...
متن کاملResults of Photorefractive Keratectomy plus Mitomycin-C in the Treatment of Regressed Refractive Errors after Laser in Situ Keratomileusis
Purpose: To investigate the application of mitomycin-C 0.02% (MMC) in the photorefractive keratectomy (PRK) procedure in correcting regressed myopia Methods: Eighteen eyes of 11 patients with a spherical equivalent (SE) of less than -5 diopters (D) who had undergone laser in situ keratomileusis (LASIK) more than 2 years before were operated on. At the end of the PRK procedure, MMC was applied o...
متن کاملPhotorefractive Keratectomy (PRK) Retreatment of Residual Refractive Errors after Laser in Situ Keratomileusis (LASIK)
Laser in situ keratomileusis (LASIK) is the most frequently performed corneal refractive procedure. Despite technological improvements, residual postoperative refractive errors are still an issue that needs to be dealt with, especially when they interfere with the patient ́s quality of life. Retreatment after LASIK is commonly performed by lifting the flap created during the first operation foll...
متن کاملcollocation errors in translations of the holy quran
the present study aims at identifying, classifying and analyzing collocation errors made by translators of the holy quran into english.findings indicated that collocationally the most acceptablt translation was done by ivring but the least appropriate one made by pickthall.
منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of current ophthalmologyجلد ۲۲، شماره ۳، صفحات ۹-۱۲
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023