comparison of intraoperative retinal break formation during standard 20-gauge and 23-gauge sutureless vitrectomy systems
نویسندگان
چکیده
purpose : the aim of this study was to compare the rate and location of intraoperatively induced retinal breaks between two techniques of standard 20-gauge vitrectomy and transconjunctival 23-gauge using trocar/cannula methods : in this prospective comparative case series patients having attached retina before surgery who were operated for different vitreoretinal or macular conditions by standard 20-gauge trans-pars plana vitrectomy (20g) were compared with another group of patients who were operated by 23-gauge using trocar/cannula system. the peripheral retina was examined before surgery and by the end of surgery using indirect ophthalmoscope and scleral depression. the rate of iatrogenic break formation, number and type of breaks and location of breaks were compared between the two groups. results : a total of 115 vitrectomies were studied. fifty five vitrectomies were done by transconjunctival micro-incision vitrectomy systems (mivs) and 60 were performed by standard 20g system. the overall rate of iatrogenic break formation was two (3.6%) and seven (11.7%) for 23-gauge and 20-gauge system, respectively. eleven breaks in 20g group were either dialysis behind or tears within one clock hour from the sclerotomy site, while the two patients in 23-gauge group had tears away from the sclerotomy site (p<0.05). no patient in the 23-gauge group showed iatrogenic dialysis. conclusion : twenty-three gauge vitrectomy may have the potential benefit of lower complication in terms of sclerotomy related breaks and retinal dialysis formation. this benefit should be weighed against the limitations and other potential complications of this technique. further studies are required to assess their safety and other complications of these systems. iranian journal of ophthalmology 201224(3):27-32 © 2012 by the iranian society of ophthalmology
منابع مشابه
Comparison of Intraoperative Retinal Break Formation during Standard 20-Gauge and 23-Gauge Sutureless Vitrectomy Systems
Purpose: The aim of this study was to compare the rate and location of intraoperatively induced retinal breaks between two techniques of standard 20-gauge vitrectomy and transconjunctival 23-gauge using trocar/cannula Methods: In this prospective comparative case series patients having attached retina before surgery who were operated for different vitreoretinal or macular conditions by standard...
متن کاملSutureless 23-gauge versus 20-gauge vitrectomy with silicone oil injection in rhegmatogenous retinal detachment.
PURPOSE To report the efficacy of 23-gauge (G) pars plana vitrectomy with silicone oil injection in rhegmatogenous retinal detachment. METHODS Retrospective chart review of consecutive patients with retinal detachment who underwent pars plana vitrectomy by one of two surgeons using distinct and consistent methods. All patients undergoing 23-G pars plana vitrectomy did not have scleral bucklin...
متن کاملUnexplained postoperative retinal hemorrhage after 23-gauge sutureless vitrectomy
We report five cases of unexplained retinal hemorrhage after 23-gauge sutureless vitrectomy. A 23-gauge sutureless vitrectomy was performed for four cases of macular holes (MH) and one case of macular hole retinal detachment (MHRD). Retinal hemorrhages were observed on the first day after surgery and disappeared within several months without leaving any recognizable damage. We speculate that th...
متن کامل23-Gauge Sutureless Vitrectomy and 20-Gauge Conventional Vitrectomy: A Case Series Comparison of Post Operative Intraocular Pressure
Purpose: To directly compare the post operative intraocular pressure (IOP) after 20and 23-gauge vitrectomy. Methods : This study is a randomized prospective study that included 60 eyes of 54 patients, these patients were recruited from the outpatient clinic of Kasr Al-Aini University hospital & International Eye Hospital. Patients were divided randomly into two groups: Group A: Scheduled for 20...
متن کاملComparison of the 20-Gauge Conventional Vitrectomy Technique with the 23-Gauge Releasable Suture Vitrectomy Technique
PURPOSE To compare the efficacy of the transconjunctival releasable suture technique for pars plana vitrectomy using 23-gauge (23G) instruments versus the conventional 20-gauge (20G) technique. METHODS A retrospective and interventional case series was consecutively performed for 199 eyes of the 192 patients that were a part of this study. Clinical data were reviewed retrospectively regarding...
متن کاملComparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
BACKGROUND To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic r...