comparison of intraocular pressure measurements by the ocular response analyzer and goldmann applanation tonometer after penetrating keratoplasty in keratoconic patients

نویسندگان

سپهر فیضی

sepehr feizi محمد پاکروان

mohammad pakravan

چکیده

purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 keratoconic eyes of 36 patients (24 men and 12 women) undergoing pkp, iop using the gat (iop gat) and corneal hysteresis (ch), corneal resistance factor (crf), goldmann-related iop (iopg), and cornea-compensated iop (iopcc) using the ora and central graft thickness (cgt) were measured. bland-altman and mountain plots were used to evaluate agreement between the tonometers. the correlation of graft curvature and astigmatism cgt and corneal biomechanical properties with iop readings was investigated using multivariate regression analysis. results : the mean age of patients was 29.8±6.1 years and they were followed up for 91.2±35.4 months postoperatively. mean ch, crf, and cgt were 10.2±2.1 mmhg, 10.1±2.2 mmhg, and 567.5±38.8 μm, respectively. mean iop gat, iopg, and iopcc were 12.2±2.4, 15.1±3.5, and 15.8±3.3 mmhg, respectively (p<0.001). the 95% limit of agreement between iop gat and iopg ranged from -3.6 to 9.3 mmhg. ch and crf, but not cgt or keratometric astigmatism were significantly associated with iop gat, iopg, and iopcc. conclusion : following pkp in keratoconus, graft biomechanics had more influence on iop values than anatomical features. in comparison to the gat, the ora yielded higher iop values.   iranian journal of ophthalmology 201224(3):19-26 © 2012 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

intraocular pressure measurements after penetrating keratoplasty using the ocular response analyzer versus goldmann applanation tonometer

purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 kerat...

متن کامل

Comparison of the ocular response analyzer and the Goldmann applanation tonometer for measuring intraocular pressure after deep anterior lamellar keratoplasty.

PURPOSE To compare intraocular pressure (IOP) measured using the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) with that measured using the Goldmann applanation tonometer (GAT) in keratoconic eyes after deep anterior lamellar keratoplasty (DALK) and evaluate the influence of central graft thickness (CGT), corneal astigmatism, corneal hysteresis (CH), and corneal r...

متن کامل

Goldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes.

PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a c...

متن کامل

Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...

متن کامل

Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in glaucoma

Purpose. To compare the intraocular pressure (IOP) readings taken by ICare, Pascal dynamic contour tonometer (DCT), and ocular response analyzer (ORA) with those taken by Goldmann applanation tonometer (GAT). We sought to evaluate the influence of central corneal thickness (CCT) on IOP measurements and to compare patients’ preferences for the four tonometers. Methods. In this prospective study,...

متن کامل

Comparison of Intraocular Pressure Fluctuations Measured by Goldmann Applanation Tonometer and Pulsatile Ocular Blood Flow Analyser

BACKGROUND Intraocular pressure (IOP) is the major known risk factor in glaucoma and the primer mover of the functional damage in glaucomatous patients but it is not a unique determinant of glaucomatous damage. Clinical assessment of glaucoma patients may not be a true reflection of overall IOP control. Evaluation of the effect of glaucoma medication is restricted by measurement of IOP as a dyn...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۴، شماره ۳، صفحات ۱۹-۲۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023