predictability, stability and safety of myoring implantation in keratoconic eyes during one year follow-up

نویسندگان

سحر مجلد نوبری

sahar mojaled nobari

consuelo villena خسرو جدیدی

khosrow jadidi

چکیده

purpose: to assess the stability of visual and refractive outcomes that was compared between three and 12 months after myoring implantation in moderate and severe keratoconus methods: this study included 54 eyes of 50 patients (27 males and 23 females) with stage ii and iii keratoconus who underwent myoring (dioptex gmbh) implantation. clinical outcomes including uncorrected distance visual acuity (udva), corrected distance visual acuity (cdva), manifest refraction, spherical equivalent (se) and mean keratometry (k)- readings were compared preoperatively and postoperatively (follow-up times were at 1, 3, 6 and 12 months postoperation). results: the mean age was 28.48±6.3. the mean udva (logmar) and the mean cdva (logmar) improved significantly from 1.20±0.24 to 0.20±0.09 and from 0.58±0.22 to 0.14±0.06, respectively (p<0.001). both se and the maximum keratometry (k)-reading decreased significantly by six diopters (p<0.001). there was no significant difference in visual and refractive outcomes between three and 12 months postoperatively. twelve months after myorig implantation the predictability was 47 eyes (87%) within ±1.00 d and 31 eyes (57%) within ±0.50 d of emmetropia.  conclusion: myoring implantation in keratoconic patients improves se, udva and cdva significantly. additionally, the improvement in udva was remarkable (approximately 10 lines). the procedure was safe and effective in treatment of patients with moderate and severe keratoconus. the visual and refractive outcomes remained stable between three and 12 months postoperatively.    iranian journal of ophthalmology 201426(3):136-43 © 2014 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictability, Stability and Safety of MyoRing Implantation in Keratoconic Eyes During One Year Follow-Up

Purpose: To assess the stability of visual and refractive outcomes that was compared between three and 12 months after MyoRing implantation in moderate and severe keratoconus Methods: This study included 54 eyes of 50 patients (27 males and 23 females) with stage II and III keratoconus who underwent MyoRing (Dioptex GmbH) implantation. Clinical outcomes including uncorrected distance visual acu...

متن کامل

Clinical outcomes of MyoRing implantation in keratoconic eyes by using the Femtosecond laser technology

Purpose: To assess the outcomes of the insertion of the MyoRing (DIOPTEX, GMBH, Linz, Austria) by applying the Femtosecond Laser Technology (FLT) method in eyes that have keratoconus problem. Methods: A prospective, nonrandomized, clinical examination was managed. 27 eyes of 15 subjects with stable keratoconus (6 females and 9 males), with lifetimes differing from 14 to 49 years were involved. ...

متن کامل

One-Year Follow-Up of Radiologic and Clinical Findings in Children with Prenatal and Neonatal Hydronephrosis

Background & Aims: Hydronephrosis is a common problem in prenatal and newborn infants diagnosed by ultrasonography. Bladder to ureter reflux, the upper or lower urinary tract obstruction, and neurogenic bladder are the most common causes of hydronephrosis in newborns and infants. Methods: In this study, 100 neonates and infants with hydronephrosis were observed clinically and laboratorically fo...

متن کامل

FOLLOW UP OF ONE HUNDRED CORNEAL AND SCLERAL RUPTURES DURING 1988-1990

In a retrospective study, one hundred corneosclerallaceration (CSL) cases were managed at Zahedan Ophthalmic Center from 1988-1990. Our findings showed that CSL is more commonly seen in young and male patients. Seasonal variation in CSL frequency with higher prevalence in the fust half of the years was evident. Also it was found that cataract was more common in corneal lacerations while hyp...

متن کامل

Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up.

PURPOSE To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction. SETTING Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS This study evaluated patients with bilateral age-related cataract who had cataract surgery with i...

متن کامل

Visual Outcomes and Complications of Spherical Intraocular Collamer Lens Implantation ( ICL ) , One Year Follow up .

479 Abstract Aim: This is a Prospective nonrandomized clinical study designed to assess the safety and efficacy of the Implantable collamer Lens (ICL) to treat moderate to high myopia. Material and Methods: It included fifty eyes from 31 patients with between -5.50 and -21.0 diopters (D) of myopia without or with astigmatism up to -2.0 diopters. The Main Outcome Measures were Uncorrected visual...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۶، شماره ۳، صفحات ۱۳۶-۱۴۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023