validity of uncorrected visual acuity measured in vision screening programs for detecting refractive errors

نویسندگان

مهدی خبازخوب

mehdi khabazkhoob حسن هاشمی

hassan hashemi یداله محرابی

yadollah mehrabi بابک عشرتی

babak eshrati کوروش اعتماد

چکیده

purpose: uncorrected visual acuity is the only variable measured in vision screening programs in many countries worldwide. the aim of this study was to calculate the sensitivity, specificity, and predictive value of the uncorrected visual acuity in the screening programs for the diagnosis of refractive errors. methods: in this cross-sectional study, of 4,157 students in the first year of primary school who were selected from seven cities of iran through multistage cluster sampling, 3,675 students participated in the study. in each school, measurement of corrected and uncorrected visual acuity, cycloplegic and non-cycloplegic refraction, and cover test were performed for all students by an optometrist. refractive errors obtained by cycloplegic refraction were considered gold standard and the validity of uncorrected visual acuity measured in the screening program for the diagnosis of refractive error was calculated. results: in students with visual acuity of 20/20, the prevalence of myopia, hyperopia and astigmatism was 1.14%, 8.07% and 11.11%, respectively. the sensitivity of uncorrected visual acuity in the screening program for the diagnosis of myopia, hyperopia, astigmatism, and ametropia was 25.33%, 12.81%, 14.34%, and 12.64%. the area under the roc curve of uncorrected visual acuity by optometrist and the screening program only showed a significant difference in myopia (p=0.013).  conclusion: the measurement of visual acuity in screening programs is not useful per se in the diagnosis of refractive errors and has a high percentage of false negative results. adding refractive error examinations to the protocol of screening programs can increase their efficacy.   iranian journal of ophthalmology 201426(3):121-8 © 2014 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of Uncorrected Visual Acuity Measured in Vision Screening Programs for Detecting Refractive Errors

Purpose: Uncorrected visual acuity is the only variable measured in vision screening programs in many countries worldwide. The aim of this study was to calculate the sensitivity, specificity, and predictive value of the uncorrected visual acuity in the screening programs for the diagnosis of refractive errors. Methods: In this cross-sectional study, of 4,157 students in the first year of primar...

متن کامل

prevalence of uncorrected refractive errors in schoolchildren a crucial vision screening to consider!

purpose : to determine the prevalence of the uncorrected refractive errors in bojnourd students methods : in a cross-sectional study, the samples were selected proportionate to the population of the schools using stratified randomized cluster sampling. the target population was the primary and junior high school students of the city of bojnourd. visual acuity (va) (snellen chart) and cycloplegi...

متن کامل

Screening for Significant Refractive Error Using a Combination of Distance Visual Acuity and Near Visual Acuity

PURPOSE To explore the effectiveness of using a series of tests combining near visual acuity (NVA) and distance visual acuity (DVA) for large-scale screenings for significant refractive error (SRE) in primary school children. METHOD Each participant underwent DVA, NVA and cycloplegic autorefraction measurements. SREs, including high myopia, high hyperopia and high astigmatism were analyzed. C...

متن کامل

The prevalence of uncorrected refractive errors in underserved rural areas

Purpose To determine the prevalence of uncorrected refractive errors, need for spectacles, and the determinants of unmet need in underserved rural areas of Iran. Methods In a cross-sectional study, multistage cluster sampling was done in 2 underserved rural areas of Iran. Then, all subjects underwent vision testing and ophthalmic examinations including the measurement of uncorrected visual ac...

متن کامل

Global magnitude of visual impairment caused by uncorrected refractive errors in 2004.

Estimates of the prevalence of visual impairment caused by uncorrected refractive errors in 2004 have been determined at regional and global levels for people aged 5 years and over from recent published and unpublished surveys. The estimates were based on the prevalence of visual acuity of less than 6/18 in the better eye with the currently available refractive correction that could be improved...

متن کامل

Visual Acuity Measures Do Not Reliably Detect Childhood Refractive Error - an Epidemiological Study

PURPOSE To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS The Northern Ireland Childhood Errors of Refraction (NICER) study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۶، شماره ۳، صفحات ۱۲۱-۱۲۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023