in vivo dosimetry evaluation of external photon treatments of brain, pelvis and breast cancer with diode dosimeters
نویسندگان
چکیده
background: delivering the maximum dose to tumor while achieving the minimum dose delivery to normal tissue; is the most important goal in external radiotherapy. diode in vivo dosimetry is widely considered to be an important tool for quality improvement of patient care in external radiotherapy. uncertainty in dose delivery should fall within 5% of the prescribed dose as recommended by international commission of radiological units and measurement (icru). materials and methods: in vivo dosimetry was implemented for treatments of 36 pelvis and 38 breast cancer patients which were treated by 60 co photon irradiation and 38 brain cancer patients which were treated by 6mv photon irradiation. the diode dosimeters that were used in this study were two different models of ptw products, t60010l model was used for 60 co photon beam and t60010m model was used for 6mv photon beams. results: the frequency histograms of the relative difference between the expected and measured doses at breast, pelvis and brain treatments, have mean values and standard deviations of -1.21% ( 7.01%), -0.44% ( 4.06%) and -1.32% ( 5.08%) , respectively. our study showed that the accurate prediction of the dose value at breast cancer treatment is harder than that at brain and pelvis cancer treatment and requires an estimation of the lack of scatter due to missing tissue. conclusions: quantitative verification of the prescribed daily dose is important in external radiotherapy to ensure precision in patient set-up accuracy in dose delivery.
منابع مشابه
the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region
چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...
15 صفحه اولIn vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy.
The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...
متن کاملIn vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity
Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...
متن کاملAchievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...