the calculation and comparison of integral dose for the rectum, bladder, right and left femur heads in two methods of prostate cancer radiotherapy: s.a.s imrt vs. 3d crt
نویسندگان
چکیده
the aim of radiation therapy treatment planning is to achieve an optimal balance between delivering a high dose to target volume and a low dose to healthy tissues. in order to refrain any complications resulting from the dose to the surrounding normal organs, the role of treatment plan has been critically evaluated in term of how large the volume or mass of normal tissues exposed in the radiation. the integral dose, hence, is one of the important guidance for predicting the radiation effects and choosing the treatment plan. the goal of this study is to compare and investigate the integral doses in conformal 3d vs. imrt plan. dosimetric data from five patients of prostate cancer, treated by simultaneous integrated boost imrt and 3d crt were evaluated in this prospective study. target volume and organs at risk were contoured using m.i.r.s treatment planning system (module integrated radiotherapy system version 5.0.00). a dose of 80 gy to the ptv1, 57 gy to rtv2 and 62 gy to the ptv3 and 70gy in 3d crt and for p v, was prescribed. for each patient imrt plans using s.a.s (dynamic step and shoot) and 3d crt with 6, 10 and 18mv energies, were done. to calculate the id to the normal healthy tissue all the target volumes were achieved. the integral dose was calculated as the mean- dose times the volume of the structure. a total of thirty imrt and 3d crt plans were performed for evaluation. the mean id received by rectum for 3d crt was almost 1.04% greater than imrt while in bladder mean value of id for imrt is also bigger than 3d crt approximately about 1.04%. in rfh and lfh the mean values of id for 3d crt were almost 1.05% and 1.06% greater than imrt, respectively. due to the three ptvs in imrt the integral dose in target volume has the biggest value comparing with 3d crt, considerably.
منابع مشابه
comparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولStep-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
متن کاملthe evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine
abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...
15 صفحه اولon the comparison of keyword and semantic-context methods of learning new vocabulary meaning
the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...
15 صفحه اولComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کاملa case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar
بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
basic and clinical cancer researchجلد ۵، شماره ۴، صفحات ۱۰-۱۸
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023