corneal pachymetry using ultrasound vs orbscan ii in normal and post-lasik eyes
نویسندگان
چکیده
purpose: to compare orbscan ii (o ii) and ultrasound (us) pachymetry in normal and post-lasik eyes. methods: in a comparative prospective study, central corneal thickness (cct) was measured in 168 eyes of 84 normal subjects and 42 eyes without corneal opacity of 21 post-lasik patients by o ii and us. paired t test was used to identify significant differences between the two methods and pearson test was used to identify the correlation of measurments between the two methods. results: mean cct measured by ultrasound (538.7 ± 47.4 mm) was less than that of o ii (542.7 ± 52.2 mm) in the normal eyes (p<0.04), but mean cct measured by ultrasound (477.8 ± 38.2 mm) was greater than that of o ii (469.5 ± 47.2 mm) in the post-lasik eyes. (p<0.02) there was significant linear correlation between us and o ii in both groups. (r=0.87, p=0.000 and r=0.88, p=0.000, respectively). conclusion: mean difference of cct measurements between o ii and us in normal and post-lasik clear cornea is not clinically significant and interchangeable use of data in planning or assessing corneal surgery is possible.
منابع مشابه
Measurement of Central Corneal Thickness Using Ultrasound Pachymetry and Orbscan II in Normal Eyes
PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...
متن کاملThe shape of posterior corneal surface in normal, post-LASIK, and post-epi-LASIK eyes.
PURPOSE. To evaluate the shape of the posterior corneal surface in eyes with normal myopia or myopic astigmatism and the changes after LASIK and epi-LASIK. METHODS. A total of 152 eyes were included in the study. The posterior corneal elevation was measured with Scheimpflug imaging (Pentacam; Oculus, Wetzlar, Germany), before LASIK or epi-LASIK and at 1 and 6 months after surgery, along the fou...
متن کاملCentral and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry.
PURPOSE To compare thickness measurements of the central 6.0 mm of the cornea obtained with the Orbscan(R) II topography system and topographical ultrasound pachymetry. SETTING School of Optometry, University of Santiago de Compostela, Galicia, Spain. METHODS In 24 right eyes, pachymetric measurements were taken at the center and 1.2 mm and 3.0 mm on the superior and inferior hemimeridians....
متن کاملCentral corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.
PURPOSE To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR. METHODS Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb...
متن کاملComparison of central corneal thickness measurements using Pentacam and ultrasonic pachymetry in post-LASIK eyes for myopia.
PURPOSE To compare central corneal thickness (CCT) measurements obtained using the Pentacam Scheimpflug system with those obtained using DGH ultrasound pachymetry (UP) in post-laser in situ keratomileusis (LASIK) eyes for myopia. METHODS In a prospective study, measurement agreement was assessed in 143 eyes of 72 post-LASIK patients using both the Pentacam and UP at the Eye Consultants Center...
متن کاملComparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes
PURPOSE To compare the precision of central corneal thickness (CCT) measurements taken with the handheld ultrasound pachymeter (USP), ultrasound biomicroscopy (UBM), and the Artemis-2 very high frequency ultrasound scanner (VHFUS) on normal subjects. DESIGN Prospective study. METHODS One eye from each of 61 normal subjects was randomly selected for this study. The measurements of the CCT we...