success rate and complications of single-plate molteno tube implantation in patients with glaucoma

نویسندگان

حیدر امینی

h amini تهران- میدان قزوین- بیمارستان فارابی- مرکز تحقیقات چشم دانشگاه علوم پزشکی تهران یدالله اسلامی

y eslami دانشگاه علوم پزشکی تهران محمدرضا رازقی نژاد

mr razeghinejad دانشگاه علوم پزشکی شیراز مریم خردپژوه

m kheradpajooh

چکیده

purpose: to evaluate the success rate and complications of single-plate molteno tube implantation in patients with intractable glaucoma. methods: this study was conducted on records of patients who underwent molteno tube implantation from 1995 to 2000 and had at least 18 months of follow-up. results: thirty six eyes of 35 patients including 20 male and 15 female subjects with mean age of 29.7±25.3 yr (range 3-77 yr) were enrolled in the study. intraocular pressure (iop) was 34.48±10.39 mmhg with use of 2.3±0.8 drugs which decreased to 17.97±7.63 mmhg with 1.9±1.2 drugs after 32.8±16.14 months of follow-up. (p< 0.0001) complete success (iop £ 21 mmhg without medication), qualified success (iop £ 21 mmhg with medication), and total success rates (summation of complete and qualified success rates) were 19.5%, 55.6%, and 75%, respectively. at final follow-up, visual acuity was improved ≥ 1 line in 10 (27.8%), decreased ≥ 1 line in 8 (22.2%) and remained unchanged in 18 (50%) eyes. postoperative complications occurred in 20 eyes (55.6%) including encapsulated bleb in 10 (27.8%), tube-iris touch in 4 (11%), flat anterior chamber in 3 (8.4%), tube-corneal touch in 2 (5.6%), and retinal detachment, tube-lens touch, and tube blockage each in 1 (2.8%). intraocular pressure dropped to zero in one eye and vision was lost. conclusion: in eyes at high risk for trabeculectomy failure, implantation of the molteno tube can be considered as a procedure with high success for controlling intraocular pressure and preservation of vision. long term follow up is recommended to ensure adequate management of the frequent complications of this procedure.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ahmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study.

PURPOSE To report 2-year follow-up data after Ahmed valve implantation (New World Medical, Inc) and Molteno single-plate implantation surgical treatment of refractory glaucoma. DESIGN Prospective, randomized, comparative study. METHODS Patients with refractory glaucoma, defined as uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite maximal antiglaucoma medication, previous...

متن کامل

Supra-tenon capsule placement of original Molteno vs Molteno 3 tube implants in black patients with refractory glaucoma: a single-surgeon experience.

OBJECTIVE To evaluate the efficacy of supra-Tenon capsule placement of original Molteno vs Molteno 3 tube implants (Molteno Ophthalmic, Dunedin, New Zealand) in black patients with refractory glaucoma. METHODS A retrospective study comparing the efficacy of supra-Tenon capsule placement of the original Molteno tube implant (130-mm(2) plate size) with the newer Molteno 3 tube implant (175-mm(2...

متن کامل

Single stage insertion of the Molteno tube for glaucoma and modifications to reduce postoperative hypotony.

Severe glaucoma was controlled in all 13 cases following insertion of a Molteno drain in a single stage procedure. One eye required a repeat operation. A modified technique to minimise early postoperative hypotony and prevent flat anterior chambers is described.

متن کامل

Surgical technique: complex glaucoma case requiring Molteno drainage tube extension

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had...

متن کامل

Correlation between Endometrial Parameters in Doppler Sonography and Success Rate of Implantation in Assisted Reproductive Programs

Background Levels of serum gonadotropins have direct effects on testicular functions and spermatogenesis. Assessment of levels of serum gonadotropins from fathered subjects and infertile patients indicates wide range diversity. In this study, we tried to find out whether the levels of seminal FSH and LH affect the parameters of seminal fluid analysis (SFA) and if there is any correlation betwee...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۱، شماره ۳، صفحات ۳۴۶-۳۵۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023