range of motion in ocular implants following enucleation: hydroxyapatite vs porous polyethylene (medpor)

نویسندگان

علی اکبر صابرمقدم

aa saber moghadam مشهد- بلوار قرنی- بیمارستان چشم خاتم الانبیا (ص)- مرکز تحقیقات چشم شهرام سازنده

sh sazandeh مشهد- بلوار قرنی- بیمارستان چشم خاتم الانبیا (ص)- مرکز تحقیقات چشم

چکیده

purpose: to compare the range of motion of hydroxyapatite (ha) and porous polyethylene (medpor) ocular implants in enucleated eyes. methods: this comparative study was performed on records of 34 patients who underwent unilateral enucleation and implantation of hydroxyapatite (13 cases) or medpor (21 cases). the two groups were compared regarding age, gender, cause of enucleation, laterality, and movement. results: patients were male in 55.9%. mean age of patients was 29.7 year (1-61 years). the most common cause of enucleation was trauma (55.9%) and the most common complication was mucopurulent discharge (14.7%). there was no case of extrusion, migration or exposure. moderate to good motility was achieved in 89.3% of patients in the medpor group and 86.6% in the ha group. there was no statistically difference between the two group regarding upward movement (p=0.68), downward movement (p=0.62), adduction (p=0.17) and abduction (p=0.65). conclusion: medpor and hydroxyapatite ocular implants are comparable regarding range of motion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

complications of hydroxyapatite and medpor ocular implants following enucleation

purpose: to compare complications and motility of hydroxyapatite versus medpor ocular implants after enucleation at ahvaz imam hospital (from jan 2010 to jun 2011). methods: in a clinical trial, 50 patients scheduled for enucleation were randomly divided in two groups of 25 patients. group 1 underwent enucleation + hydroxyapatite (ha) and group 2 underwent enucleation + medor implant. all patie...

متن کامل

Postoperative rotation of hydroxyapatite enucleation implants.

OBJECTIVE To determine the incidence of postoperative rotation of flattened hydroxyapatite enucleation implants. METHODS A retrospective review of patients receiving flattened hydroxyapatite enucleation implants was performed to determine the incidence and severity of postoperative implant misalignment. RESULTS Flattened hydroxyapatite implants had been placed in 16 patients. Five were note...

متن کامل

Cranioplasty with the Medpor porous polyethylene flexblock implant. Technical note.

The authors describe the use of a porous polyethylene Flexblock implant for cosmetic cranioplasty. The implant may be used to cover any small- or medium-sized (< 8 cm) cranial defect, offering similar cosmetic results to standard alloplast cranioplasty while decreasing operation time. The porous implant design permits ingrowth of soft tissue and bone to increase implant strength and decrease th...

متن کامل

Comparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyes.

PURPOSE Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance. METHODS Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, a...

متن کامل

The use of porous polyethylene (Medpor) lower eyelid spacers in lid heightening and stabilisation.

BACKGROUND/AIMS The management of lower eyelid retraction can be challenging, and established techniques to correct it are not always successful. Previous reports have suggested a role for the ultrathin high density porous polyethylene lower eyelid spacer (Medpor LES) in such patients. The authors report the experience of three surgeons implanting Medpor LES over 1 year, and ascertain whether s...

متن کامل

Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant expos...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۲، شماره ۱، صفحات ۷۶-۸۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023