comparison of visual outcomes between aspheric iols: tecnis z9000 and acrysof iq

نویسندگان

محمدرضا جعفری نسب

mr jafarinasab تهران- پاسداران- بوستان نهم- بیمارستان لبافی نژاد- مرکز تحقیقات چشم احمدرضا باقی

ar baghi تهران- پاسداران- بوستان نهم- بیمارستان لبافی نژاد- مرکز تحقیقات چشم فرید کریمیان

f karimian تهران- پاسداران- بوستان نهم- بیمارستان لبافی نژاد- مرکز تحقیقات چشم مهدی یاسری

m yaseri تهران- پاسداران- بوستان نهم- بیمارستان لبافی نژاد- مرکز تحقیقات چشم

چکیده

purpose: to compare tecnis z9000 and acrysof iq aspheric intraocular lenses (iols) regarding spherical aberration and contrast sensitivity. methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned to implantation of tecnis or iq iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 mm pupil diameters) and contrast sensitivity in photopic and mesopic conditions at spatial frequencies of 1, 2, 5, 10 and 20 cycles per degree (cpd) were determined. results: mean bcva was 0.083±0.071 logmar in the iq group and 0.076±0.080 logmar in the tecnis group (p=0.338). spherical aberration in the tecnis group was smaller with pupil diameter of 4 mm (0.140±0.097 µm vs 0.183±0.107 µm, p= 0.609) but greater with pupil diameter of 6 mm (0.303±0.183 µm vs 0.26±0.069 µm, p= 0.40) as compared to the iq group. contrast sensitivity was higher in the tecnis group at 1, 2 and 5 cpd under photopic (not significant) and mesopic (p<0.001, p<0.08, p=0.2, respectively) conditions. conversely, contrast sensitivity was higher in the iq group at 10 and 20 cpd under photopic and mesopic conditions (not significant). conclusion: tecnis or iq iols seem to be comparable in terms of spherical aberration and contrast sensitivity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of visual outcomes between aspheric iols: tecnis z9000 versus akreos ao

purpose: to compare tecnis z9000 and akreos ao aspheric intraocular lenses (iols) in terms of spherical aberration and contrast sensitivity. methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned for implantation of tecnis or akreos ao iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 an...

متن کامل

comparison of visual outcomes between aspheric iols: acrysof iq and akreos ao

purpose: to compare acrysof iq and akreos ao aspheric intraocular lenses (iols) in terms of spherical aberration and contrast sensitivity. methods: thirty-seven eyes of 37 patients undergoing phacoemulsification cataract surgery were randomized to implantation of acrysof iq or akreos ao iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 m...

متن کامل

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

PURPOSE TO COMPARE SPHERICAL ABERRATION AND CONTRAST SENSITIVITY WITH TWO DIFFERENT TYPES OF ASPHERIC POSTERIOR CHAMBER INTRAOCULAR LENSES (PCIOLS): Tecnis Z9000 versus Akreos AO. METHODS Thirty-four eyes of 34 patients undergoing phacoemulsification for senile cataracts were randomly assigned to implantation of Tecnis Z9000 or Akreos AO PCIOLs. Outcome measures included best-corrected visual...

متن کامل

visual outcomes of aspheric iol (acrysof iq) versus spheric iol (sensar) implantation

purpose: to compare acrysof iq and sensar intraocular lens (iols) in terms of spherical aberration and contrast sensitivity.  methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned for implantation of acrysof iq or sensar iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 mm pupil d...

متن کامل

Aspheric versus Spherical Posterior Chamber Intraocular Lenses

PURPOSE To compare spherical aberration and contrast sensitivity function following implantation of four different foldable posterior chamber intraocular lenses (IOLs), namely Sensar, Akreos AO, Tecnis, and AcrySof IQ. METHODS In this randomized clinical trial, 68 eyes of 68 patients with senile cataracts underwent phacoemulsification and IOL implantation with Sensar (n=17), Akreos AO (n=17),...

متن کامل

Cataract Surgery Feature Story

SEPTEMBER 2009 I CATARACT & REFRACTIVE SURGERY TODAY EUROPE I 31 O ur visual system integrates the refractive surfaces of the cornea and the crystalline lens; the positive spherical aberration (SA) of the cornea is partially cancelled out by the negative SA of the crystalline lens.1,2 As the eye ages, the cornea remains fairly stable, but the crystalline lens thickens at the periphery, inducing...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۳، شماره ۲، صفحات ۱۸۶-۱۹۱

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023