comparison of visual outcomes between aspheric iols: acrysof iq and akreos ao
نویسندگان
چکیده
purpose: to compare acrysof iq and akreos ao aspheric intraocular lenses (iols) in terms of spherical aberration and contrast sensitivity. methods: thirty-seven eyes of 37 patients undergoing phacoemulsification cataract surgery were randomized to implantation of acrysof iq or akreos ao iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 mm pupil diameters) and contrast sensitivity in photopic and mesopic conditions at spatial frequencies of 1, 2, 5, 10 and 20 cycles per degree (cpd) were determined. result: mean bcva was 0.083±0.071 logmar in the iq group and 0.115±0.090 logmar in the ao group (p=0.338). spherical aberration with both 4 and 6 mm pupil diameters was lower in the iq group as compared to the ao group (0.183±0.107 µm vs 0.285±0.087 µm, p<0.001 and 0.26±0.096 µm vs 0.329±0.083 µm, p=0.40, respectively). contrast sensitivity was significantly higher in the iq group at 1, 2 and 10 cpd under photopic and at 1, 10 and 20 cpd under mesopic conditions as compared to the ao group. conclusions: the acrysof iq seems to have better visual outcomes in terms of spherical aberration and contrast sensitivity as compared to akreos ao.
منابع مشابه
comparison of visual outcomes between aspheric iols: tecnis z9000 versus akreos ao
purpose: to compare tecnis z9000 and akreos ao aspheric intraocular lenses (iols) in terms of spherical aberration and contrast sensitivity. methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned for implantation of tecnis or akreos ao iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 an...
متن کاملcomparison of visual outcomes between aspheric iols: tecnis z9000 and acrysof iq
purpose: to compare tecnis z9000 and acrysof iq aspheric intraocular lenses (iols) regarding spherical aberration and contrast sensitivity. methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned to implantation of tecnis or iq iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 mm pu...
متن کاملAspheric versus Spherical Posterior Chamber Intraocular Lenses
PURPOSE To compare spherical aberration and contrast sensitivity function following implantation of four different foldable posterior chamber intraocular lenses (IOLs), namely Sensar, Akreos AO, Tecnis, and AcrySof IQ. METHODS In this randomized clinical trial, 68 eyes of 68 patients with senile cataracts underwent phacoemulsification and IOL implantation with Sensar (n=17), Akreos AO (n=17),...
متن کاملVisual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO
PURPOSE TO COMPARE SPHERICAL ABERRATION AND CONTRAST SENSITIVITY WITH TWO DIFFERENT TYPES OF ASPHERIC POSTERIOR CHAMBER INTRAOCULAR LENSES (PCIOLS): Tecnis Z9000 versus Akreos AO. METHODS Thirty-four eyes of 34 patients undergoing phacoemulsification for senile cataracts were randomly assigned to implantation of Tecnis Z9000 or Akreos AO PCIOLs. Outcome measures included best-corrected visual...
متن کاملvisual outcomes of aspheric iol (acrysof iq) versus spheric iol (sensar) implantation
purpose: to compare acrysof iq and sensar intraocular lens (iols) in terms of spherical aberration and contrast sensitivity. methods: thirty-four eyes of 34 patients undergoing phacoemulsification cataract surgery were randomly assigned for implantation of acrysof iq or sensar iols. three months postoperatively, best-corrected visual acuity (bcva), spherical aberration (with 4 and 6 mm pupil d...
متن کاملA comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery
PURPOSE Akreos AO and Kontur AB are two commonly used intraocular lenses (IOLs) in Iran. This study was designed to evaluate the visual performance of these lenses. METHODS In a comparative interventional study, 35 patients (70 eyes) were recruited, and each IOL was implanted in one eye of the patients, randomly. Best corrected visual acuity (BCVA), contrast sensitivity, aberrometric analysis...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۳، شماره ۲، صفحات ۱۸۱-۱۸۵
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023