purpose: to assess hoffer correction factor in measurement of axial length (al) in eyes with phakic iol implants. methods: in this descriptive historical cohort study, axial length was measured by ultrasound (us) and iol master in both phakic and pseudophakic modes in 24 eyes of 14 patients with artisan intraocular lenses (iols) implanted for refractive purposes, hoffer’s suggested formula for correcting ultrasound al was applied to the data (cor-us) and all four datasets were compared to preoperative ultrasound al values as standards. results: the mean difference between preoperative ultrasound measurements and postoperative readings by us (alpo), iolmaster in phakic mode (al iolmp), iol master in pesudophakic mode (al iolmpp) and us corrected with hoffer factor (alhc), were 0.01, 0.022, 0.13, and 0.61mm, with mean absolute differences of 0.23, 0.23, 0.26, and 0.25mm, respectively. in these readings, respectively 42.3%, 37.5%, 57.5%, and 46.2% of differences were greater than 0.2 mm, which is considered to be clinically important. discussion: use of the hoffer correction factor has no clinical application for a more accurate biometry in patients with an artisan implant. the most reliable method in this type of patients is making an accurate record of their preoperative al measured with ultrasound or iol master.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations

PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...

متن کامل

Biometry of phakic intraocular lens using Scheimpflug photography.

PURPOSE To examine lateral and axial positioning of phakic intraocular lenses (IOLs) with iris fixation in the anterior chamber and to examine short-term stability of the IOL position. SETTING The Netherlands Opthalmic Research Institute, Amsterdam, the Netherlands. METHODS Thirty patients participated in the study. Thirty-one eyes were implanted with the 204 type myopia IOL, 14 eyes with t...

متن کامل

Experience with the Artisan phakic intraocular lens in Asian eyes.

PURPOSE To investigate the efficacy and safety of implantation of an iris-claw phakic intraocular lens (PIOL), Artisan Myopia, in Asian eyes. SETTING Minamiaoyama Eye Clinic, Tokyo, Japan. METHODS Forty-four eyes of 32 Japanese patients and 1 Korean patient with high myopia had Artisan Myopia lens implantation to correct their refractive errors. Lens models, 5/8.5 or 6/8.5 (optic diameter/o...

متن کامل

Lens vacuoles during phakic intraocular lens implantation

Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۵، شماره ۳، صفحات ۱۵۹-۱۶۶

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023