correlation between corneal power and corneal diameter

نویسندگان

محسن فروردین

farvardin shiraz university of medical sciences, shiraz, iranشیراز- مرکز تحقیقات چشم پزشکی پوستچی فاطمه جمالی پور

jamalipour shiraz university of medical sciences, shiraz, iranشیراز- مرکز تحقیقات چشم پزشکی پوستچی علیرضا آستانه

astaneh shiraz university of medical sciences, shiraz, iranشیراز- مرکز تحقیقات چشم پزشکی پوستچی مهناز مصلایی

mossalaei shiraz university of medical sciences, shiraz, iranشیراز- مرکز تحقیقات چشم پزشکی پوستچی نوشین طاهری

چکیده

purpose: to evaluate the correlation between corneal power and corneal horizontal white to white diameter in myopic patients scheduled for lasik surgery. methods: overall, in 840 eyes of 420 myopic subjects scheduled for lasik, horizontal white to white diameter and mean corneal power were obtained using orbscan ii. pearson correlation test and regression analysis were used to detect any correlation between corneal power and corneal diameter. results: mean spherical equivalent refractive error was -4.56±1.4 (range, -1 to -10.75) diopter, while mean keraometeric value was 43.69±1.5 (range, 40-47.2). a significant negative linear correlation was found between corneal power and white to white diameter as follows: corneal diameter= 65.79-(1.88×corneal power); r=0.204. conclusion: the negative linear correlation between mean corneal power and corneal white to white diameter may have clinical implications in refractive surgery for selection of a suitable microkeratome.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between Corneal Radius of Curvature and Corneal Eccentricity

Aim: The primary aim of this study was to find if there is any correlation between the corneal radius of curvature and its eccentricity. Method: 45 subjects participated in this study, 24 emmetropes, 18 myopes and three hyperopes. All subjects were free of ocular abnormalities and had no media opacities. All the subjects had normal ocular health and good visual acuity of 1.0 or better for both ...

متن کامل

Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter.

PURPOSE To evaluate the relationship between the horizontal ciliary sulcus diameter and anterior chamber diameter measured by 35 MHz ultrasound biomicroscopy (UBM) and the horizontal corneal diameter (white to white [WTW]) measured by scanning-slit topography and to assess the repeatability (intraexaminer difference) of the 2 methods. SETTING Department of Orthoptics and Visual Science, Kitas...

متن کامل

Corneal diameter in premature infants.

The size of the cornea is important in the diagnosis of primary infantile glaucoma. Reference values regarding eyes of premature infants are scarce. Such data are of special importance in areas such as the Middle East where infantile glaucoma is common and often evident already at birth. The authors have measured the horizontal corneal diameter of the eyes of 127 premature Saudi infants with a ...

متن کامل

The correlation between IOP measurement, central corneal thickness and corneal curvature.

In a prospective study we measured the intraocular pressure (IOP), the central corneal thickness (CCT) and the central corneal curvature in 172 myopic eyes before and after LASIK treatment. We find a significant decrease in intraocular pressure. Statistical evaluation reveals a linear correlation between the IOP decrease and the amount of stromal ablation. The IOP and corneal curvature are meas...

متن کامل

Primary Corneal Keloid

Purpose: To report the clinical presentation, histopathologic findings, and surgical treatment in a series of cases with primary corneal keloid. Case Reports: Six Iranian patients (a father and two sons, a mother and her daughter, and one isolated male patient) without any history of corneal trauma or systemic diseases were clinically and histologically evaluated for a slowly-growing, white opa...

متن کامل

Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfaces.

A knowledge of the shape of the cornea is of major importance for the planning and monitoring of surgery, and for the correct diagnosis of corneal diseases. Many authors have studied the geometry of the second corneal surface in the central region and it has been stated that there is a high correlation between the central radii of curvature and asphericities of the two corneal surfaces. In this...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
بینا

جلد ۱۶، شماره ۲، صفحات ۱۲۰-۱۲۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023