chemical structure and optical properties of hydrophilic and hydrophobic intraocular lenses
نویسندگان
چکیده
purpose: to compare the optical properties of hydrophilic and hydrophobic intraocular lenses (iols) containing uv-absorber and to determine their chemical composition. methods: optical properties of different foldable hydrophilic and hydrophobic as well as non-foldable hydrophobic polymethylmetacrylate (pmma) iols were evaluated in three powers of 15, 22 and 25 diopters. optical properties were measured using uv-vis (uv-visible) spectroscopy between wavelengths 200 and 800 nm and chemical structure characteristics were determined by atr (attenuated total reflectance) spectroscopy. results: atr spectroscopy revealed that foldable hydrophilic and hydrophobic iols and non-foldable hydrophobic iols were respectively composed of hydroxyethylmethacrylate, a copolymer of phenylethylacrylate and phenylethylmethacrylate, and pmma (in accordance with manufacturer’s claim). cut-off points of the lenses were found to be around 350-420 nm. increasing the iol power from 15 to 22 diopters did not significantly change the cut-off points of foldable hydrophobic iols, however a considerable cut-off shift to higher wavelengths was noted when power increased to 25 diopters. pmma lenses showed a constant cut-off at 400 nm for all power values. conclusion: the increase in power is associated with absorption of lower energy uv radiation and shift of cut-off points to higher wavelengths in hydrophobic iols but with no considerable effect on cut-off points in pmma iols.
منابع مشابه
extraction and acetylation of purified trypsin from bovin pancreas and study of some its physico-chemical properties
آنزیم تریپسین در شرایط قلیایی ناپایدار می باشد .و فعالیت پروتئولیتیکی تریپسین منجربه خود هضمی آن در جایگاههای خاصی می گردد. بنابر این آنزیمی با ناپایداری بالا محسوب میگردد. در سالهای اخیر موفق شدند که با ایجاد تغیرات شیمیایی با اضافه کردن فلزات خاص ، کلسیم و یا عمل استیلاسیون منجر به افزایش پایداری آنزیم تریپسین گردند. مطالعات در حال حاضر نشان می دهد که تریپسین استیله شده فعالیت آنزیمی خود را ...
15 صفحه اولComparison of the long-term clinical results of hydrophilic and hydrophobic acrylic intraocular lenses.
This study was performed to compare the incidence of posterior capsular opacity (PCO) and refractive errors between hydrophilic (ACR6D, Corneal) and hydrophobic (MA60BM, AcrySof) acrylic intraocular lenses (IOLs) over a 3-year follow-up after phacoemulsification surgery. The patients with AcrySof implanted in one eye and Corneal in the other eye were categorized as Group 1 (n=28), while those w...
متن کاملNeodymium: YAG capsulotomy rates after phacoemulsification with hydrophobic and hydrophilic acrylic intraocular lenses.
PURPOSE To retrospectively evaluate the incidence of neodymium: YAG (ND:YAG) laser capsulotomies for posterior capsule opacification (PCO) seen with hydrophobic and hydrophilic acrylic intraocular lens implants 18 months after surgery. METHODS One hundred and five eyes that had phacoemulsification with a continuous curvilinear capsulorhexis and implantation of either a hydrophobic or a hydrop...
متن کاملEvaluating and defining the sharpness of intraocular lenses: microedge structure of commercially available square-edged hydrophilic intraocular lenses.
PURPOSE To evaluate the microstructure of the edges of currently available hydrophilic acrylic intraocular lenses (IOLs) in terms of their deviation from an "ideal" square as a follow-up of preliminary in vitro studies of experimental poly(methyl methacrylate) IOLs and commercially available foldable hydrophobic IOLs. SETTING Berlin Eye Research Institute, Berlin, Germany. METHODS Twenty-fo...
متن کاملBacterial adhesion to surface hydrophilic and hydrophobic contact lenses.
The aim of this paper was to determine the adhesion of two physico-chemically characterized bacterial strains to a surface hydrophilic (CL A, water contact angle 57 degrees) and hydrophobic (CL B, water contact angle 106 degrees) hydrogel contact lens (CL) with and without an adsorbed tear film in a parallel plate flow chamber. Hydrophobicity (by water contact angles), charge (by particulate mi...
متن کاملOptical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study
BACKGROUND The opacification of hydrophilic intraocular lenses (IOLs) is a very rare complication in terms of absolute numbers. We report on the analyses of opacified Euromaxx ALI313Y and ALI313 IOLs (Argonoptics, Germany) using light and scanning electron microscopy, X-ray spectroscopy and optical bench analysis. METHODS Opacified Euromaxx ALI313Y and ALI313 IOLs were explanted after patient...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۶، شماره ۴، صفحات ۳۴۴-۳۵۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023