intraocular pressure measurements after penetrating keratoplasty using the ocular response analyzer versus goldmann applanation tonometer

نویسندگان

سپهر فیضی

s feizi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم محمد پاکروان

m pakravan ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم پرویز ملکی فر

p malekifar ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم محمدعلی جوادی

ma javadi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم

چکیده

purpose: to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and to evaluate the influence of anatomical and biomechanical properties of the grafts on iop measurements. methods: this cross-sectional study was conducted on 45 keratoconic eyes undergoing pkp. iop was measured using the gat (iop gat); corneal hysteresis (ch), corneal resistance factor (crf), goldmann-related iop (iopg), and cornea-compensated iop (iopcc) were obtained using the ora; central graft thickness (cgt) was measured by ultrasonic pachymetry. bland-altman and mountain plots were used to evaluate agreement between the tonometers. the correlation of graft curvature and astigmatism; central graft thickness (cgt); and corneal biomechanical properties with iop readings was investigated using multivariate regression analysis. results: mean patient age was 29.8±6.1 years and mean follow up was 91.2±35.4 months. mean ch, crf, and cgt were 10.2±2.1 mmhg, 10.1±2.2 mmhg, and 565.4±37.7 mm, respectively. mean iop gat, iopg, and iopcc were 12.2±2.4, 15.1±3.5, and 15.8±3.3 mmhg, respectively (p<0.001). the 95% limit of agreement between iop gat and iopg ranged from -3.6 to 9.3 mmhg. ch and crf, but not cgt or keratometric astigmatism were significantly associated with iop gat, iopg, and iopcc. conclusion: graft biomechanics had more influence on iop values as compared to anatomical features. in comparison to gat, the ora seem to overestimate iop in post-pkp eyes. key words: intraocular pressure, ocular response analyzer, penetrating keratoplasty

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

comparison of intraocular pressure measurements by the ocular response analyzer and goldmann applanation tonometer after penetrating keratoplasty in keratoconic patients

purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 kera...

متن کامل

Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...

متن کامل

Comparison of the ocular response analyzer and the Goldmann applanation tonometer for measuring intraocular pressure after deep anterior lamellar keratoplasty.

PURPOSE To compare intraocular pressure (IOP) measured using the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) with that measured using the Goldmann applanation tonometer (GAT) in keratoconic eyes after deep anterior lamellar keratoplasty (DALK) and evaluate the influence of central graft thickness (CGT), corneal astigmatism, corneal hysteresis (CH), and corneal r...

متن کامل

Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements.

PURPOSE To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central cornea...

متن کامل

Goldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes.

PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a c...

متن کامل

Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in glaucoma

Purpose. To compare the intraocular pressure (IOP) readings taken by ICare, Pascal dynamic contour tonometer (DCT), and ocular response analyzer (ORA) with those taken by Goldmann applanation tonometer (GAT). We sought to evaluate the influence of central corneal thickness (CCT) on IOP measurements and to compare patients’ preferences for the four tonometers. Methods. In this prospective study,...