visual outcomes of femto-lasik after peneterating keratoplasty
نویسندگان
چکیده
purpose: to determine the outcomes of visual correction with femto-lasik following pk. methods: in this prospective study, 34 eyes of 31 patient who had undergone thin – flap lasik due to high refractive error after corneal grafting were evaluated .after complete ocular examination and assessment of uncorrected and corrected distant visual acuity (ucva and bcva) , the patients underwent femto-lasik using the ziemer femto-ldv with 100 micron flap thickness. result: after 3 to 19 (10.14±4.81) months of follow-up, mean ucva increased from 1.5 log mar preoperatively (5/100) to 0.3 logmar (5/10) postoperatively (p<0.05). mean bcva also increased from 0.3 logmar (5/10) to 0.1 logmar (8/10) (p<0.05). mean spherical equivalent changed from -6.98±3.87 to -2.18±2.69 and mean of defocus equivalent also decreased from 10.32±3.74 preoperatively to 4.13±2.93 postoperatively (p<0.05 for both). no significant intraoperative and postoperative complications occurred. conclusion: femto-lasik surgery after penetrating keratoplasty is a successful procedure for correction of moderate to high refractive errors. it seems to be clinically safe, effective and predictable.
منابع مشابه
Two-step LASIK after penetrating keratoplasty
PURPOSE The point of interest of this retrospective case review is to study refractive changes caused by the hinged lamellar keratotomy and the refractive outcome after laser ablation in a second step within the scope of laser in situ keratomileusis (LASIK) in patients with penetrating keratoplasty. METHODS Data from eight patients obtained before lamellar keratotomy, before laser ablation, a...
متن کاملvisual outcomes of lasik in myopic eyes
purpose: to evaluate the visual outcomes of lasik in myopic eyes. methods: this interventional case series was performed on records of 345 eyes of 179 patients for correcting myopia with astigmatism < 3.00 diopter (d). all patients were operated by one surgeon (h.n.) with the nidek ec 5000 excimer laser. all patients had at least one year follow up. based on preoperative refraction, patients we...
متن کاملComparison of visual acuity, refractive outcomes, and satisfaction between LASIK performed with a microkeratome and a femto laser
PURPOSE To compare refractive outcomes, visual acuities, and satisfaction of patients between those treated with laser-assisted in situ keratomileusis (LASIK) using a Hansatome microkeratome (HM) and femto-assisted laser (FAL). METHODS This was a retrospective analysis of 1,366 eyes in 687 patients who underwent LASIK with an HM (n=1,137) and an FAL (n=229) at the two centers of Hashmanis Hos...
متن کاملDeterminants of visual quality after endothelial keratoplasty.
Endothelial keratoplasty is now favored over full-thickness penetrating keratoplasty for corneal decompensation secondary to endothelial dysfunction. Although endothelial keratoplasty has evolved as surgeons strive to improve outcomes, fewer patients than expected achieve best corrected visual acuity of 20/20 despite healthy grafts and no ocular comorbidities. Reasons for this remain unclear, w...
متن کاملvisual outcomes after successful versus failed big-bubble deep anterior lamellar keratoplasty in keratoconus
purpose: to compare visual outcomes after deep anterior lamellar keratoplasty (dalk) between eyes with and without successful big-bubble formation. methods: in this retrospective comparative study, a total of 290 consecutive eyes from 257 keratoconus-affected patients underwent dalk with the big-bubble technique were enrolled. in cases where the big bubble could not be accomplished, manual stro...
متن کاملEffect of keratometry on visual outcomes 1 month after hyperopic LASIK.
PURPOSE To determine whether preoperative, postoperative, or change in keratometry can be used to predict visual outcomes in hyperopic LASIK. METHODS A retrospective analysis was conducted on hyperopic eyes treated at Optical Express clinics. All eyes were targeted for emmetropia and treated using wavefront-guided LASIK (VISX S4, Abbott Medical Optics [AMO]), with flaps created using a femtos...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
بیناجلد ۱۷، شماره ۳، صفحات ۲۱۴-۲۱۹
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023