comparison of corneal and anterior segment parameters between pentacam and galilei
نویسندگان
چکیده
baradaran rafii ar, md; motevasseli t, md*; yazdizadeh f, md; ansari sh, md; karimian f, md; sadoughi mm, md; kiani h ocular tissue engineering research center, shahid beheshti university of medical sciences, tehran, iran * corresponding author: [email protected] purpose: to compare anterior segment indices measured by two scheimpflug camera; galilei and pentacam. methods: in this observational case series, myopic patients scheduled for refractive surgery underwent corneal and anterior segment analyses using pentacam (single scheimpflug camera) and galilei (dual scheimpflug camera). analyzed parameters included anterior and posterior best-fit spheres (bfs), axial curvature, true corneal power, central corneal thickness (cct), anterior chamber (ac) depth, ac volume, ac angle and pupil diameter. statistical analysis was performed using paired t- test and bland-altman plots. results: the study comprised 176 eyes of 88 patients. the mean radius of the anterior bfs was 7.79 ± 0.34 mm measured with pentacam and 7.75 ± 0.39 mm measured with galilei (r=0.877,p<0.001), and the mean radius of posterior bfs was 6.42 ± 0.32 mm and 6.47 ± 0.38 mm, respectively, (r=0.879,p<0.001). anterior axial curvature was 43.8 ± 1.9 d with pentacam and 43.8± 2.4 d with galilei (r=0.905,p<0.003). posterior axial curvature was 6.3 ± 0.3 d and 6.3 ± 0.4 d, respectively (r=0.873, p<0.001). true corneal power was 43.9 ± 1.9 d with pentacam and 43.5± 2.3 d with galilei (r=0.909,p<0.001). cct was 537±44 µm with pentacam and 553±51 µm with galilei (r=0.796,p<0.001). anterior chamber depth was 3.29±0.4 mm and 3.3±0.38 mm (r=0.85, p<0.001), anterior chamber volume was 207±50 mm³ and 129±39 mm³ (p=0.004), anterior chamber angle was 39.7±9.2 degree and 54.2±5.2 degree (p=0.051), respectively. average pupil diameter was 3.91±1.77 mm with pentacam and 3.34±0.89 mm with galilei (p=0.007). there was a significant correlation between all measured parameters except for cct, ac volume, ac angle, and pupil diameter. conclusion: there is a significant agreement between galilei and pentacam scheimpflug analyzers in most of the measured indices. however, the correlation can be low in some parameters. therefore, these two devices cannot be used interchangeably.
منابع مشابه
Anterior Segment Parameters Using Pentacam and Prediction of Corneal Endothelial Cell Loss after Cataract Surgery
PURPOSE We evaluated various preoperative anterior segment parameters measured with a Pentacam rotating Scheimpflug camera and compared them with those of conventional methods. We also evaluated the effect of different parameters on corneal endothelial cells after cataract surgery. METHODS Pentacam examination was performed in 88 eyes from 88 patients to evaluate central anterior chamber dept...
متن کاملTitle : the Variability of Corneal and Anterior Segment Parameters
30 Purpose: To analyse, describe and test diverse corneal and anterior segment parameters 31 in normal and keratoconic eyes to better understand the geometry of the keratoconic 32 cornea. 33 34 Method: 44 eyes from 44 keratoconic patients and 44 eyes from 44 healthy patients 35 were included in the study. The Pentacam System was used for the analysis of the 36 anterior segment parameters. New a...
متن کاملRelationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters
Purpose. To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group. Methods. This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects. The anterior segment parameters and geometric corneal parameters such as corneal vo...
متن کاملComparison between Two Scheimpflug Anterior Segment Analyzers
PURPOSE To compare the anterior segment indices measured by two Scheimpflug camera machines; Galilei and Pentacam. METHODS In this observational case series, the anterior segment indices of myopic healthy subjects seeking for refractive surgery were measured by Pentacam and Galilei on the same day. Analyzed parameters were anterior and posterior best fit spheres (BFS), axial curvature, true c...
متن کاملThe relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology
To investigate the relationship between corneal biomechanics and anterior segment parameters in the early stage of overnight orthokeratology.Twenty-three eyes from 23 subjects were involved in the study. Corneal biomechanics, including corneal hysteresis (CH) and corneal resistance factor (CRF), and parameters of the anterior segment, including corneal curvature, central corneal thickness (CCT)...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...