guide wire j-tip technique for easy exchange of in situ endotracheal tubes

نویسندگان

hamid reza eftekharian jahromi department of maxillofacial surgery, shiraz neurosciences research center, chamran hospital, shiraz university of medical sciences, shiraz, iran

چکیده

0

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guide Wire J-Tip Technique for Easy Exchange of In Situ Endotracheal Tubes

Dear Editor, Endotracheal intubation (ETI) is a simple, rapid, safe and non-surgical technique for airway management. It maintains airway patency, protects the lungs from aspiration, and permits leak-free ventilation during mechanical ventilation. The anesthesiologists’ knowledge, technical skills and crisis management capabilities play an important role in controlling the occurrence of unwante...

متن کامل

The "U-wire" technique during ERCP for easy guide wire passage through occluded uncovered metal stents.

A significant number of self-expanding metal stents (SEMSs) placed as conservative therapy for malignant biliary obstruction will become occluded [1]. Stent occlusion can be treated endoscopically either by balloon trawling to remove the biliary sludge and debris or by inserting a polyethylene stent or a second stent through the occluded stent [2]. However, these treatments can be given only af...

متن کامل

Guide Wire Induced Cardiac Tamponade: The Soft J Tip Is Not So Benign

Central venous catheter (CVC) insertion rarely causes cardiac tamponade due to perforation. Although it is a rare complication, it can be lethal if not identified early. We report a case of cardiac tamponade caused by internal jugular (IJ) central venous catheter (CVC) insertion using a soft J-tipped guide wire which is considered safe and rarely implicated with cardiac tamponade. A bedside tra...

متن کامل

Guide wire knot during double J catheter insertion: case report.

OBJECTIVE To report one case of intrapyelic loop of a guide wire during double J catheter insertion. METHODS We report the case of a 24 year-old female, with the diagnosis obstructive uropathy secondary to pelvic tumor who required double J catheter insertion for urinary diversion. A loop of the guide wire was formed during the procedure which was finally solved without aggressive measures. ...

متن کامل