investation and compare blood pressure measurements taken by both components of stethoseope, bell and diaphragm

نویسندگان

محمد رضا افاضل

afazel m

چکیده

this is a 9uasi experimental study to compare blood pressure measurements taken by both components of stethoscope, bell and diaphragm. blood pressure was evaluated in fifty patients of fifteen years of age and older. equal populations of both genders were selected randomly from infectious, surgery and internal medicine wards. subjects with cardiac arrhythmia weren&apos;t included in the study. five minutes before collecting the data subjects were in the supine position. blood pressure was measured simultaneously by using a bell and a diaphragm on both arms by two trained examiners. the cuff on each arm was connected separately to two mercury sphygmomanometers and by a y -connection to a single bulb. in order to leave out the effect of the difference in pressure in the two arms, blood pressure was measured with identical components of stethoscope at the same time, and the resulting difference was taken in to account in the computations. after computing the difference, resulting from the use of different tools bell or diaphragm) for blood pressure measurments, results showed that values measured by bell versus diaphragm in each of the three cases (systolic, first diastolic and second diastolic) were understimated (the mean difference being 0.56, 0.48 and 0.72 mmhg respectively). statistical analysis of the result by the use of paired t-test indicated that there was no significant difference among those three cases. as a result, the three research hypotheses that predicated the existance of difference between systolic, first diastolic and second diastolic recordings measured by two different techniques, the bell and the diaphrgm, were rejected (p<0.05).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood Pressure Measurements Taken by Patients are Similar to Home and Ambulatory Blood Pressure Measurements

OBJECTIVE To compare blood pressure measurements taken at home by physicians, nurses, and patients with office blood pressure measurement , ambulatory blood pressure monitoring and home blood pressure measurement. METHODS A total of 44 patients seen by a home care program were studied. Protocol 1 a) blood pressure was measured by the patient, a physician and a nurse during a regular home visi...

متن کامل

بررسی و مقایسه مقادیر فشار سیستولیک اندازه گیری شده بوسیله قسمت دیافراگم و بل گوشی در بیماران بستری در بیمارستان شهید بهشتی کاشان در سال 1372

  This is a 9uasi experimental study to compare blood pressure measurements taken by both components of stethoscope, bell and diaphragm. Blood pressure was evaluated in fifty patients of fifteen years of age and older. Equal populations of both genders were selected randomly from infectious, surgery and internal medicine wards. Subjects with cardiac arrhythmia weren't included in the study. Fiv...

متن کامل

effect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars

این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...

Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement

OBJECTIVE This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. METHODS Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Kor...

متن کامل

Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First-Morning Micturition and in the Afternoon

Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturitio...

متن کامل

constructing a cultural dimensions scale and investigating efl teacher burnout,iranian identity components, and the norms of khorasan razavi culture

این تحقیق در ساختار چهار مرحله ای خود هشت هدف را دنبال کرد: در مرحله اول، تنها هدف طراحی و معتبر سازی پرسشنامه ای بومی بر اساس مدل فرهنگی شش بعدی هافستد (2010) بود. این کار با استفاده از داده های جمع شده از 370 نفر و توسط روش آماری sem انجام شد. مرحله دوم که با استفاده از داده های جمع شده از 170 معلم زبان انگلیسی انجام شد دارای دو هدف بود: هدف اول، بررسی فرسایش کاری معلمان زبان از دید ابعاد فره...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
نشریه پرستاری ایران

جلد ۱۲، شماره ۱۸، صفحات ۱۱۵-۱۲۱

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023