design and fabrication of the mechanical part of a prototype multileaf collimator system

نویسندگان

mohammad taghi bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran

abdoreza hashemian assistant professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran

shahrokh nasseri ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran

hassan rafati hemayati m.sc. in industrial design, pouian medical equipment engineering company, mashhad, iran

چکیده

introduction: multileaf collimator (mlc) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. the purpose of this research was to design and construct the mechanical section of a prototype mlc.  material and methods: the mlc consists of a base plate, 52 leaves, 2 leaf carriages, 2 nuts and 52 triangular thread screws. the leaves are arranged in two opposing banks each containing 26 leaves. the carriages are used to extend the movement of the leaves. the components of the mlc are fabricated by machining processes. the mlc is designed to be mounted on the conventional linear accelerators as an add-on accessory. the leaves were made of aluminum. the dimensions of the leaves are 5 x 200 x 50 mm.  result: the collimator system weighs approximately 37kg excluding the leaves. the projected width of each leaf on the isocenter of a varian linear accelerator is 10 mm. the movement of the leaves is accomplished by using the triangular thread screws. the screws required to have a low axial backlash which in turn results in lower precision positioning of the leaves. the positioning accuracy of each leaf is approximately 1.4 mm. discussion and conclusion: mashhad mlc system, in it’s present form and design weighs 37 kg. but if aluminum blades are replaced by tungsten ones then the over all weights of mlc may exceed the weight limit a linac may hold. therefore futher modifications are required to reduce the mlc total weight. it is desirable to use ball screws and roller cages instead of triangular thread screws to achive a higher positioning pereision of the blades

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of the Mechanical Part of a Prototype Multileaf Collimator System

Introduction: Multileaf collimator (MLC) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. Some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. The purpose of this research was ...

متن کامل

design and fabrication of the control part of a prototype multileaf collimator system

multileaf collimator (mlc) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. the mlc system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 dc motors, 16 programmable logic controllers (plcs) and one human machine interface (hmi). this system can be mounted on conventio...

متن کامل

Design and Fabrication of the Control Part of a Prototype Multileaf Collimator System

Multileaf collimator (MLC) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. The MLC system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 DC motors, 16 programmable logic controllers (PLCs) and one human machine interface (HMI). This system can be mounted on conventio...

متن کامل

Design and fabrication of a prototype planar undulator

The main goal of this work is to get the fabrication technology of the insertion devices. A prototype undulator with the period of 48mm and the peak magnetic field of 0.75 T has been fabricated using NdFeB-SH35 magnets based on the cooperation between ILSF and NSTRI. The total magnet length is 483 mm and the number of periods is 8. The magnetic parameters of the undulator are determined in orde...

متن کامل

a study on the design of bio-ethanol process from date wastes of sistan and baluchistan province

اتانول کاربردهای متنوعی در صنایع لاستیک سازی، رنگسازی، حلالها ومکمل سوخت خودرو دارد. اتانول برخلاف نفت از جمله مواد تجدیدپذیر محسوب می شود که مشکلات زیست محیطی و آلودگی نیز ایجاد نمی کند. استفاده از اتانول به عنوان مکمل سوختخودروها از جمله مهمترین مصارف صنعتی این ماده بشمار می رود. با توجه به این موضوع تحقیق و توسعه در زمینه تولید اتانول با درجه خلوص بالا در سطح جهان، و نه تنها در کشور های پیشر...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۴، شماره Issue ۳,۴، صفحات ۱۱-۱۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023