an assessment of the photon contamination due to bremsstrahlung radiation in the electron beams of a neptun 10pc linac using a monte carlo method
نویسندگان
چکیده
introduction: in clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. this bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs, even for the same electron beam energy. the aims of this study were to simulate the neptun 10pc linac electron beams and to calculate the photon contamination dose due to bremsstrahlung radiation in these beams using a monte carlo method. materials and methods: a neptun 10pc linac was simulated in its electron mode using the beamnrc code. this linac can provide three electron beam energies of 6, 8 and 10 mev. detailed information required for the simulation, including the geometry and materials of various components of the linac treatment head, was provided by the vender. for all simulations, the cut-off energies for electron and photon transport were set at ecut=0.521 mev and pcut=0.010 mev, respectively. the ks statistical test was used for validation of the simulated models. then, relevant bremsstrahlung radiation doses for the three electron beam energies of the linac were calculated for the reference field using the monte carlo method. results: the ks test showed a good agreement between the calculated values (resulting from the simulations) and the measured ones. the results showed that the amount of contaminated photon dose due to bremsstrahlung radiation from various components of the simulated linac at the surface of the phantom was between 0.2%-0.5% of the maximum dose for the three electron beam energies. conclusion: considering the good agreement between the measured and simulated data, it can be concluded that the simulation method as well as the calculated bremsstrahlung doses have been made at a good level of accuracy and precision. the results of this study indicate that photon contamination in the neptun 10pc electron beams is not significant. therefore, it seems that this linac can be used for total skin electron irradiation.
منابع مشابه
An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملMonte Carlo modeling of electron beams from a NEPTUN 10PC medical linear accelerator
Electron beam radiation therapy is used extensively for treating head and neck cancers to avoid the irradiation of the spinal cord. It is also used for treating chest wall malignancies to limit the irradiated volume of lungs. Calculating the dose distribution from an electron field is quite complicated because of the multiple scattering, especially in the presence of internal heterogeneities [1...
متن کاملThe influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method
In radiation therapy with high-energy photon beams (E > 10 MV) neutrons are generated mainly in LINACs head thorough (γ,n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the AAPMTG-34 report, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pac...
متن کاملThe influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method
Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...
متن کاملEvaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
متن کاملfrom linguistics to literature: a linguistic approach to the study of linguistic deviations in the turkish divan of shahriar
chapter i provides an overview of structural linguistics and touches upon the saussurean dichotomies with the final goal of exploring their relevance to the stylistic studies of literature. to provide evidence for the singificance of the study, chapter ii deals with the controversial issue of linguistics and literature, and presents opposing views which, at the same time, have been central to t...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۶، شماره ۱، صفحات ۲۱-۳۲
میزبانی شده توسط پلتفرم ابری doprax.com