dosimetric comparison of various radiotherapeutic treatment plans using cobalt-60 and linac for prostate cancer
نویسندگان
چکیده
introduction: this study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (id), homogeneity index (hi) and conformity index (ci) in various treatment plans for prostate cancer. materials and methods: pelvic computed tomography (ct) scans of 27 patients were acquired and transferred to the rtdoseplan treatment planning system. for each patient, 8 conventional plans (3, 4, 5 and 6 fields) were planned for the cobalt-60 photon energy. subsequently, the same plans were performed for 6 mv and 18 mv photon energies. results: by increasing the energy of the beam relative to the cobalt-60 energy, the dmean values for rectum and bladder were reduced from 3% to 4% and 4% to 6%, respectively, the dose received by the whole of the bladder volume decreased by 26% for 6 mv and by 58% for 18 mv. increasing the photon beam energy decreased ci to 7% and 10%, id was decreased by10% and 20% and dmax was decreased by 3% and 4%, respectively. discussion and conclusion: a six-field treatment plan in comparison to the other plans offers the minimum dose to critical organs and sufficient dose to the prostate. increasing the photon energy improves the treatment parameters of the bladder and the ptv.
منابع مشابه
Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کاملAnalysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans
Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...
متن کاملRadiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans
Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...
متن کاملComparison of conventional and 3D conformal treatments using linac energies for prostate cancer
Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...
متن کاملcomparison of zoe and vitapex for canal treatment of necrotic primary teeth
چکیده ندارد.
15 صفحه اولDosimetric and physical comparison of IMRT and CyberKnife plans in the treatment of localized prostate cancer.
AIM The aim of our study was the dosimetric and physical evaluation of the CK and IMRT treatment plans for 16 patients with localized prostate cancer. BACKGROUND Intensity modulated radiation therapy (IMRT) is one of the recent technical advances in radiotherapy. The prostate is a well suited site to be treated with IMRT. The challenge of accurately delivering the IMRT needs to be supported b...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۶، شماره ۲، صفحات ۷۱-۷۹
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023