introduction: intensity modulated radiation therapy (imrt) is one of the cancer treatment methods. it is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (mlc). materials and methods: in order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investigated in this work. design and simulation of an mlc was performed by a monte carlo method and the optimum material for manufacturing the leaves was determined using mcnp4c. after image processing (ct or mri) in this system, the tumor configuration is determined. then the linear accelerator is switched on and the beam irradiates the cancerous cells. when the mlc leaves receive a command from the microcontroller, they start to move and absorb the radiation and modulate its intensity. consequently, the tumor receives maximum intensity of radiation but minimum intensity is delivered to healthy tissues. results: according to the simulations and calculations, the best material to manufacture the leaves from is tungsten alloy containing copper and nickel which absorbs a large amount of the radiation; by using a 8.65 cm thickness of alloy, 10.55% of radiation will transmit through the leaves. discussion and conclusion: lead blocks are conventionally used in radiotherapy. however, they have some problems like cost, storage and manufacture for every patient. certainly, the mlc is the most efficient device to specifically irradiate the tumor in imrt. furthermore, it facilitates treating the target in different views by rotation around the patient. thus the patient’s absorbed dose will decrease and the tumor will receive maximum dose.
منابع مشابه
Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy
Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...
متن کاملMinimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator.
This paper proposes a sequencing algorithm for intensity-modulated radiation therapy with a multileaf collimator in the static mode. The algorithm aims to minimize the number of segments in a delivery sequence. For a machine with a long verification and recording overhead time (e.g., 15 s per segment), minimizing the number of segments is equivalent to minimizing the delivery time. The proposed...
متن کاملDetermination of depth and field size dependence of multileaf collimator transmission in intensity‐modulated radiation therapy beams
Intensity-modulated radiation therapy (IMRT) plans for the treatment of large and complex volumes may contain a relatively large contribution from multileaf collimator (MLC) transmission. In such cases, comprehensive characterization of direct and scatter MLC transmission is important. We designed a set of tests (open beam, closed static MLC, and dynamic MLC gap) to determine dosimetric MLC pro...
متن کاملImpact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-MV Intensity-Modulated Radiation Therapy Treatment Plans
The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC) transmission and rounded leaf offset in a commercial treatment planning system (TPS) (Pinnacle3, Philips Medical Systems, Andover, MA, USA) on the accuracy of intensity-modulated radiation therapy (IMRT) dose calculation. The MLC leaf transmission factor was modified ...
متن کاملA deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery.
PURPOSE To develop a deliverable four-dimensional (4D) intensity-modulated radiation therapy (IMRT) planning method for dynamic multileaf collimator (MLC) tumor tracking delivery. METHODS AND MATERIALS The deliverable 4D IMRT planning method involves aligning MLC leaf motion parallel to the major axis of target motion and translating MLC leaf positions by the difference in the target centroid...
متن کاملFLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...