gamma knife simulation using the mcnp4c code and the zubal phantom and comparison with experimental data

نویسندگان

somayeh gholami m.sc., nuclear engineering dept., shahid beheshti university, tehran, iran

alireza kamali asl assistant professor, nuclear engineering dept., shahid beheshti university, tehran, iran

seyed mahmood aghamiri assistant professor, nuclear engineering dept., shahid beheshti university, tehran, iran

mahmood allahverdi assistant professor, medical physics dept., tehran university, tehran, iran

چکیده

introduction: gamma knife is an instrument specially designed for treating brain disorders. in gamma knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. the tumor is placed at the isocenter and is treated by the emitted gamma rays. therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surrounding the tumor. material and method: in the current work, the mcnp simulation code was used to simulate the gamma knife. the calculated values were compared to the experimental ones and previous works. dose distribution was compared for different collimators in a water phantom and the zubal brain-equivalent phantom. the dose profiles were obtained along the x, y and z axes. result: the evaluation of the developed code was performed using experimental data and we found a good agreement between our simulation and experimental data. discussion: our results showed that the skull bone has a high contribution to both scatter and absorbed dose. in other words, inserting the exact material of brain and other organs of the head in digital phantom improves the quality of treatment planning. this work is regarding the measurement of absorbed dose and improving the treatment planning procedure in gamma-knife radiosurgery in the brain.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data

Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...

متن کامل

Comparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

متن کامل

on the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors

the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...

15 صفحه اول

Monte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code

Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...

متن کامل

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۷، شماره ۲، صفحات ۵۷-۶۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023