dosimetric comparison of 3d tangential radiotherapy of post-lumpectomy breast at two different energies
نویسندگان
چکیده
introduction: radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. a tangential parallel-opposed pair is almost always the technique of choice for this purpose. this technique is often performed based on 3d treatment planning. the aim of this study was to compare 3d treatment planning for two different energies (cobalt 60 versus 6 mv photon beams) in tangential irradiation of breast conserving radiotherapy. in this comparison, homogeneity of isodoses within the breast volume and dose received by lungs were considered. materials and methods: in this study, twenty patients with breast cancer treated with conservative surgery were included. a ct scan was performed on selected patients. three-dimensional treatment planning with 6 mv photon beams was carried out for patients on the eclipse 3d treatment planning system (tps). the volumes receiving lower than 95% (vol<95) (cold areas) and greater than 105% (vol>105) (hot areas) of the reference dose, and the volume of lung receiving ≥30gy (vol≥30gy) were derived from dose volume histograms (dvhs). dose homogeneity index was calculated as: dhi = 100 – (vol>105 + vol<95). in the second stage, each patient was replanned with cobalt 60 and the quantities of interest were obtained from the dvhs. results: comparing 3d treatment planning by 6 mv and cobalt 60 photons, cold areas were reduced (p<0.001), hot areas were decreased (p<0.7), dhi was improved (p<0.001) and vol≥30gy was reduced (p<0.017) with 6 mv photons. discussion and conclusion: our results indicate that treatment planning with cobalt 60 causes more cold areas in the treated volume as compared with 6 mv photons. cold areas within the target volume of the breast result in reduced tumor control probability. the plan can be optimized to limit dose to lung volume by using 6 mv photons. so lung fibrosis is more likely to occur with cobalt 60. in addition, dhi was improved with 6 mv photon beams. improvement of dose homogeneity can lead to higher tumor control probability and cosmetic results, and less skin and lung side effects. hence, 3d treatment planning with 6 mv photon beams is a more suitable option for patients with breast cancer treated with conserving surgery
منابع مشابه
Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملDosimetric comparison of treatment of left breast cancer using two different dose schedules Dosimetric comparison of treatment of left breast cancer using two different dose schedules
Background: To date, different kinds of treatment methods have been proposed for radiotherapy of cancer patients. Choosing the kind of treatment method affects the quality of the patient's treatment. This study aims to investigate the effect of the number of radiation treatment sessions on the dose received by the patient and the distribution of tumor dose and dose received by organs at risk in...
متن کاملComparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study
Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...
متن کاملDosimetric Comparison of Two Craniospinal Radiotherapy Techniques for Treatment Optimization
Introduction: Orthogonal radial fields are those in which the central axes are perpendicular to each other. An example of these orthogonal fields is the set of craniospinal orthogonal fields that are used for radiotherapy of medulloblastoma. Craniospinal radial fields consist of two parallel-opposed fields for brain exposure and one or two posterior spinal fields for spinal cord exposure. The m...
متن کاملA comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center
Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...
متن کاملTangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: A dosimetric comparison
BACKGROUND This study evaluates the dose distribution of reversed planned tangential beam intensity modulated radiotherapy (IMRT) compared to standard wedged tangential beam three-dimensionally planned conformal radiotherapy (3D-CRT) of the chest wall in unselected postmastectomy breast cancer patients METHODS For 20 unselected subsequent postmastectomy breast cancer patients tangential beam ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۸، شماره ۲، صفحات ۱-۸
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023