simulation of the bnct of brain tumors using mcnp code: beam designing and dose evaluation

نویسندگان

seyed farhad masoudi physics department, k.n. toosi university of technology, tehran, iran

چکیده

introduction bnct is an effective method to destroy brain tumoral cells while sparing the healthy tissues. the recommended flux for epithermal neutrons is 109 n/cm2s, which has the most effectiveness on deep-seated tumors. in this paper, it is indicated that using d-t neutron source and optimizing of beam shaping assembly (bsa) leads to treating brain tumors in a reasonable time where all iaea recommended criteria are met. materials and methods the proposed bsa based on a d-t neutron generator consists of a neutron multiplier system, moderators, reflector, and collimator. the simulated snyder head phantom is used to evaluate dose profiles in tissues due to the irradiation of designed beam. monte carlo code, mcnp-4c, was used in order to perform these calculations.   results the neutron beam associated with the designed and optimized bsa has an adequate epithermal flux at the beam port and neutron and gamma contaminations are removed as much as possible. moreover, it was showed that increasing j/φ, as a measure of beam directionality, leads to improvement of beam performance and survival of healthy tissues surrounding the tumor. conclusion according to the simulation results, the proposed system based on d-t neutron source, which is suitable for in-hospital installations, satisfies all in-air parameters. moreover, depth-dose curves investigate proper performance of designed beam in tissues. the results are comparable with the performances of other facilities.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Introduction BNCT is an effective method to destroy brain tumoral cells while sparing the healthy tissues. The recommended flux for epithermal neutrons is 109 n/cm2s, which has the most effectiveness on deep-seated tumors. In this paper, it is indicated that using D-T neutron source and optimizing of Beam Shaping Assembly (BSA) leads to treating brain tumors in a reasonable time where all IAEA ...

متن کامل

Simulation of the BNCT of Brain Tumors Using MCNP Code: Beam Designing and Dose Evaluation

Introduction BNCT is an effective method to destroy brain tumoral cells while sparing the healthy tissues. The recommended flux for epithermal neutrons is 10 n/cms, which has the most effectiveness on deep-seated tumors. In this paper, it is indicated that using D-T neutron source and optimizing of Beam Shaping Assembly (BSA) leads to treating brain tumors in a reasonable time where all IAEA re...

متن کامل

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

on the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors

the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...