silastic thickness optimization in uveal melanoma brachytherapy by monte carlo method
نویسندگان
چکیده
introduction in order to treat uveal melanoma , first, radioactive seeds are laid on a silicone- made substance which is called silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. the dose gradient within the tumor and healthy tissues can be varied due to changing the silastic thickness between sclera surface and radioactive seeds. in turn, this leads to difference in the amount of absorbed dose of tumor and healthy tissues. present study is to investigate the optimum silastic thickness in uveal melanoma brachytherapy. materials and methods to measure changes of depth dose of the plaque in a sphere with a radius of 12 mm, mcnp4c code was applied. exact specifications of a 20-mm collaborative ocular melanoma study (coms) plaque, silastic and three i-125 seed sources, 6711 model were integrated in simulation. dose calculations were performed using f6 tally in spheres with a radius of 0.2 mm. results by measuring the changes of dose rate of plaque in distances of 0.2 to 18 mm from the sclera surface and having the prescribed dose for the absolute treatment of eye melanoma, final absorbed doses by tumor and healthy tissues for each different silastic thicknesses of 0, 0.5, 1, 1.5, and 2 were calculated. conclusion considering the results and sclera tolerance, it was concluded that the thickness of silastic must not exceed 0.5 mm, because increasing the silastic thickness from this area, increases absorbed dose by healthy tissues and also the treatment time.
منابع مشابه
Silastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method
Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between scler...
متن کاملAssessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method
Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...
متن کاملNonlinear Stochastic Optimization by the Monte-Carlo Method
Methods for solving stochastic optimization problems by Monte-Carlo simulation are considered. The stoping and accuracy of the solutions is treated in a statistical manner, testing the hypothesis of optimality according to statistical criteria. A rule for adjusting the Monte-Carlo sample size is introduced to ensure the convergence and to find the solution of the stochastic optimization problem...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method
Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.
Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...
متن کاملStudy of the absorbed dose rate of all rays emitted from the 252Cf brachytherapy source by the Monte Carlo method
The 252Cf brachytherapy source is a spontaneous fission decay source, which is used as a neutron-emitting source. In addition to neutrons emitted from this source, gamma rays are also emitted with the average energy of 1 MeV. In this study, using the Monte Carlo N-Particle code (MCNPX), the absorbed dose rates of the neutrons, the primary gamma and the secondary gamma that generated by thermal ...