optimization of parameters in 16-slice ct- scan protocols for reduction of the absorbed dose
نویسندگان
چکیده
introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for the measurement of image-related parameters and ctdi phantom was utilized for the calculation of absorbed dose to patients. imaging parameters including ma (50-400 ma), pitch factor (1 and 1.5) and rotation time (range of 0.5, 0.75, 1, 1.5 and 2 seconds) were considered as independent variables. the brain, abdomen and chest imaging was performed multi-slice and spiral modes. changes in image quality parameters including contrast resolution (cr) and spatial resolution (sr) in each condition were measured and determined by matlab software. results after normalizing data by plotting the full width at half maximum (fwhm) of point spread function (psf) in each condition, it was observed that image quality was not noticeably affected by each cases. therefore, in brain scan, the lowest patient dose was in 150 ma and rotation time of 1.5 seconds. based on results of scanning of the abdomen and chest, the lowest patient dose was obtained by 100 ma and pitch factors of 1 and 1.5. conclusion it was found that images with acceptable quality and reliable detection ability could be obtained using smaller doses of radiation, compared to protocols commonly used by operators.
منابع مشابه
Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملEvaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...
متن کاملstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
Image Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۱۱، شماره Issue ۲,۳، صفحات ۲۷۰-۲۷۵
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023