local diagnostic reference levels for common pediatric x-ray examinations in khorasan razavi province, iran

نویسندگان

malakeh malekzadeh paramedical school. babol university of medical sciences. babol. iran

چکیده

introduction given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. diagnostic reference level (drl) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an area or an institution as a local drl (ldrl). materials and methods to establish drl for diagnostic x-ray examinations of children in khorasanrazavi province, data were collected from 627 pediatric patients. the average of entrance surface doses (esds), arising from chest and abdomen examinations, were examined for three different age groups. results local drl (ldrl) were calculated to be 77, 126, and 138 µgy for chest examinations of <1-month-old, 1-12-month-old, and 1-5-year-old groups, respectively. the corresponding values obtained from abdomen radiographies were 152, 120, and 280 µgy, respectively. conclusion our findings revealed that local drls in this study are higher than the corresponding values, recommended by the commission of european communities (cec) and national radiological protection board (nrbp). higher esds acquired for chest examination were related to the use of low kvp, relatively high mas in all centers, and use of grid for most of the patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...

متن کامل

Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...

متن کامل

diagnostic reference levels (drls) for routine x-ray examinations in lorestan province, iran

background: in diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. secondly estimates of the absorbed dose to tissue and organs in the patients. materials and methods: a total of 2382 patients were studied t...

متن کامل

Diagnostic reference levels for X-ray examinations in Slovenia

Background. Medical applications of ionizing radiation are by far the largest man-made source of radiation exposure for the population in most developed countries. A good practice in diagnostic radiology should produce an image containing all necessary information needed for accurate diagnosis and should result in the minimum dose to the patient. After introduction of diagnostic reference level...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۱۱، شماره ۴، صفحات ۳۰۱-۳۰۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023