using temperature of ir sources for assessing photochemical and aphakic retinal hazard
نویسندگان
چکیده
introduction blue light is a part of the spectrum with the highest energy content, which can reach the retina. the damage that it can cause to the retina is called photochemical or blue-light retinal injury. for the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (w.m-2.sr-1) seems to be slightly perplexing for ophthalmologists. however, in this study, the temperature (oc) that can emit the same effective spectral radiance limit was detected using a computer code; this method could help prevent blue-light retinal injury. materials and methods the limits proposed by international commission on non-ionizing radiation protection for blue-light induced photochemical and aphakic eye hazards were expressed in terms of temperature by a computer code for 13 planckian sources that produce the same radiance. the calculated temperature by the computer code, here known as threshold temperature, is the maximum source temperature that for a specified viewing distance and source diameter does not cause the exposure at the receptor position to exceed the exposure limit. results in terms of threshold temperature, the exposure limits for aphakia or infant retinal injury are much lower than retinal photochemical damage. for light sources with more effective radiances, these differences reach 800 k. conclusion this method allows evaluation of photochemical and aphakic retinal hazard only by comparing the calculated threshold temperature by a computer code with the temperature of the radiant source, which may be beneficial for hygienist and ophthalmic clinicians.
منابع مشابه
Using Temperature of IR Sources for Assessing Photochemical and Aphakic Retinal Hazard
Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be ...
متن کاملCompliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Aphakic retinal detachment.
A study of 132 cases of aphakic retinal detachment (ARD) following mainly intracapsular cataract surgery has been made. Forty-nine cases (37%) were found to have vitreous incarcerated into the cataract section out of a total of 54 (41%) cases who had suffered a vitreous complication during cataract surgery. A study of the characteristics of ARD reveals that those cases having had a vitreous com...
متن کاملSurgery of aphakic retinal detachment.
In a prospective study 84 patients with aphakic retinal detachment were treated either by local scleral buckling alone or combined with an encirclement. The rate of surgical reattachment of the retina was found to be similar with either technique over a minimum follow-up period of one year. Simplicity and a low incidence of serious complications of the local procedure merit its application as t...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of medical physicsجلد ۱۳، شماره ۱، صفحات ۴۳-۴۸
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023