accuracy of 180 pedicle screw placement with the assistance of plain radiography in thuracolumbar spine fractures

نویسندگان

جواد آقازاده

آدرس مکاتبه: بیمارستان امام خمینی (ره) ارومیه، بخش جراحی مغز و اعصاب، تلفن تماس 09141419284سازمان های دیگر: بیمارستان شهید مطهری ارومیه

چکیده

background & aims: thuracolumbar unstable fractures (t, l.u.f) are common after spine truma. posterior pedicular fixation is a technique that is use for fixation of these fractures. this study evaluates the accuracy of pedicular screw placement in t, luf with the assistance of plain radiography in operation rooms. materials & methods: this study is a case-control and analytical study. 35 patients with t, luf underwent fixation with 180 pedicle screws placement by s33 spinal system with the assistance of plain radiography and anatomic landmarks. results: the first plain radiography shows that accuracy point and direction of 30 screws were unsuitable. in the second radiography, after correcting the entry point and direction, 10 screws had unsuitable position. in the third radiography, 3 screws had unsuitable but acceptable position. conclusion: plain radiography and recognition of spine anatomic landmarks are helpful in accuracy posterior pedicular screw placement.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان موفقیت در جاگذاری 180 پیچ پدیکولار بکاررفته در شکستگی‌های ناپایدار ستون فقرات توراکولومبار با استفاده از رادیوگرافی ساده در حین عمل جراحی

  Background & Aims: Thuracolumbar Unstable Fractures (T, L.U.F) are common after spine truma. Posterior pedicular fixation is a technique that is use for fixation of these fractures. This study evaluates the accuracy of pedicular screw placement in T, LUF with the assistance of plain radiography in operation rooms.   Materials & Methods: This study is a case-control and analytical study. 35 pa...

متن کامل

Accuracy of pedicle screw placement in thoracolumbar spine with conventional open technique.

AIM To demonstrate the incidence of screw misplacement and revision rates in a group of 72 patients that underwent pedicle screw fixation for spinal pathologies using the conventional, fluoroscopy-guided open technique. MATERIAL AND METHODS Data from 72 consecutive patients with spinal instability that received 472 screws between April 2011 and May 2013 were reviewed and pedicle wall breach w...

متن کامل

Accuracy of pedicle screw placement in patients with Marfan syndrome

BACKGROUND There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. METHODS CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Pedicle screw placement accuracy of bone-mounted miniature robot system

This article describes factors affecting the accuracy of transpedicle screw placements performed with the Renaissance robot-guided system and reviews the relevant literature. Between January 2013 and January 2015, Renaissance robot-guided spinal surgery was performed in 125 patients at Kaohsiung Medical University Hospital in Kaohsiung, Taiwan. The surgeries included 662 transpedicle screw impl...

متن کامل

Pedicle screw placement accuracy impact and comparison between grading systems

BACKGROUND Pedicle screw instrumentation is widely used for spinal stabilization. However, the accuracy for free-hand screw placement ranges from 69% to 94%. This study assesses the value of the existing classification systems, and investigates their impact on the ability to assess the accuracy of free-hand screw placement. METHODS Data were collected retrospectively from the medical records ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله پزشکی ارومیه

جلد ۱۹، شماره ۱، صفحات ۶۷-۷۱